2 General Format<br />

<strong>AT+i</strong>[[ | #UFn]…]<br />

General Format<br />

(or ) 2–4 letter command code () or parameter name ()<br />

Delimiter: '=', '~', '?', ':', ‗,‘<br />

Optional parameter or data. If includes a , as<br />

defined above, it must be enclosed in single (‗) or double (―) quotes.<br />

The terminating is considered as a terminating quote as well.<br />

#UFn User-field macro substitution<br />

Carriage Return line terminator (ASCII 13)<br />

2.1 <strong>AT+i</strong> Commands by Category<br />

Command Function Parameters/Description<br />

<strong>AT+i</strong> Command prefix Required to precede all commands<br />

Host Interface<br />

En Echo Mode n=0 Do not echo host characters<br />

n=1 Echo all host characters (default upon power-up)<br />

This command is equivalent to and interchangeable with<br />

ATEn.<br />

=value<br />

-or-<br />

:value<br />

Parameter Database Maintenance<br />

Set parameter value stored in parameter in nonvolatile memory.<br />

retains set value indefinitely after power down.<br />

~value Assign single session<br />

parameter value<br />

value is assigned to parameter for the duration of<br />

a single Internet session. Following the session, the<br />

original value is restored.<br />

? Read parameter Parameter value is returned.<br />

=? Parameter allowed<br />

values<br />

Returns the allowed values for this parameter.<br />

FD Factory Defaults Restores all parameters to factory defaults.<br />

Status Report<br />

RP Request status report Returns a status report value based on .<br />

Connection<br />

BDRA Auto baud rate mode Forces iChip into auto baud rate detection mode.<br />

UP Connect to Internet Forces iChip to go online, establish an Internet session,<br />

and optionally register its IP address.<br />

TUP Triggered Internet Enters a mode in which iChip goes online in response to<br />

session mode<br />

triggers from external signals. It also supports a special<br />

Always Online mode.<br />

DOWN Perform a software reset Performs a software reset. Forces iChip to terminate an<br />

Internet session and go offline.<br />

PING PING a remote system Sends a PING message and waits for its echo response.<br />

<strong>AT+i</strong> Programmer‘s <strong>Manual</strong> Version 8.21 2-1