Nonvolatile Parameter Database<br />

Parameter Type Range Default Description<br />

Remote Firmware Update<br />

UEN Byte 0..1 0<br />

(Disabled)<br />

E-Mail Firmware Update Enable<br />

Remote Parameter Update<br />

RPG String 64 chars NULL E-mail Parameter Update<br />

Group/Password. Also acts as password<br />

to restrict updating the iChip parameters<br />

via a web browser.<br />

Secure Socket Protocol (SSL3/TLS1)<br />

CS Byte 0, 4, 5, 0<br />

Set the cipher suite to be used during<br />

10, 47, (propose SSL3/TLS negotiations.<br />

53 all)<br />

CA String 1300 NULL Set iChip‘s SSL3/TLS trusted<br />

characters<br />

Certificate Authority (CA).<br />

CERT String 4 Kbyte NULL Set iChip‘s SSL3/TLS certificate.<br />

PKEY String 4 Kbyte NULL Set iChip‘s private key.<br />

DHCP Server<br />

DPSZ Byte 0-255 0<br />

Set number of addresses in iChip‘s IP<br />

(DHCP<br />

server off)<br />

pool.<br />

DSLT INT 0-65535 0<br />

Define lease time, in minutes, granted<br />

(No limit) when assigning IP addresses to clients.<br />

Table 34-1 Nonvolatile Parameter Database