Nonvolatile Parameter Database<br />

Parameter Type Range Default<br />

SerialNET Mode<br />

Description<br />

HSRV or String 64 chars NULL Set the remote host server name/IP and<br />

HSRn<br />

port.<br />

HSS String 3 chars NULL Switches among three possible HSRV<br />

parameters.<br />

DSTR String 8 chars NULL Set the disconnection string template.<br />

LPRT Unsigned<br />

INT<br />

0-65535 0 Set the SerialNET mode listen socket.<br />

MBTB INT 0-2048 0 Max bytes to buffer while iChip is<br />

establishing a connection.<br />

MTTF Unsigned 0-65535 0 (None) Max inactivity timeout in milliseconds<br />

INT<br />

before flushing the SerialNET socket.<br />

FCHR Byte 1 char 0 (None) Flush character. When received,<br />

SerialNET socket will be flushed.<br />

MCBF INT 0-1460 0 (None) Max. characters before flushing the<br />

SerialNET socket.<br />

IATO INT 0-32768 0 (None) Inactivity timeout in seconds before<br />

closing the SerialNET connection.<br />

SNSI String 9 chars ―5,8,N,1,0‖ SerialNET mode Serial interface<br />

configuration. Defines baud, bits, parity,<br />

stop and flow control.<br />

STYP Byte 0..1 0 (TCP) Set the SerialNET mode socket type.<br />

0 (TCP) or 1 (UDP).<br />

SNRD INT 0..3600 0 (No Delay time in seconds before re-<br />

Delay) enabling SerialNET mode after a failed<br />

connection.<br />

SPN String 96 chars NULL SerialNET Phone Number to wake-up<br />

SerialNET Server.<br />

SDT Byte 0..255 20 SerialNET Dial Timeout. When waking<br />

up a SerialNET server, iChip will<br />

hangup after SDT seconds have elapsed.<br />

SWT INT 0..65535 600 SerialNET Wake-up Timeout. Number<br />

of seconds to allow for the SerialNET<br />

server wake-up procedure.<br />

PTD INT 0..65535 0 (No Specifies the number of Packets to Drop<br />

Filter) during a SerialNET session.