25.3 Header Parameter Names and Values<br />

Name Value Default<br />

RP_DEST Single NONE<br />

RP_GROUP<br />

string, no<br />

space<br />

characters<br />

NONE<br />

RP_START_FROM_FACTORY_DEFAULTS YES/NO NO<br />

Table 25-1 Header Parameter Names and Values<br />

iChip Parameter Update<br />

RP_GROUP — If the RPF Group Name parameter contains a value, the RPF file<br />

must include an RP_GROUP definition and its value must be identical to the RPF<br />

value. Otherwise, the parameter update file will be rejected. Nevertheless, if the RPF<br />

parameter is set to the special value (*) (match any), the RPF file will be accepted<br />

with any value of RP_GROUP, as well as without any value at all. The RPF Group<br />

Name parameter can be viewed and changed by sending an <strong>AT+i</strong>RPG? command to<br />

iChip.<br />

RP_DEST — If the RPF file contains this parameter, the parameter update file will<br />

be rejected unless the value given in this parameter is identical to the unique ID of the<br />

iChip it was sent to. The unique ID can be viewed by sending an <strong>AT+i</strong>RP5 command<br />

to iChip, but cannot be changed. This feature facilitates sending a parameter update to<br />

a specific iChip controller only.<br />

RP_START_FROM_FACTORY_DEFAULTS — This flag defines the initial<br />

value of parameters. A YES value will initially restore all iChip parameters to their<br />