21.03.2013 Views

Push Buttons—XB5 22 mm www.SquareD.com - LiveWire Electrical ...

Push Buttons—XB5 22 mm www.SquareD.com - LiveWire Electrical ...

Push Buttons—XB5 22 mm www.SquareD.com - LiveWire Electrical ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Push</strong> <strong>Buttons—XB5</strong> <strong>22</strong> <strong>mm</strong><br />

<strong>Electrical</strong> Components<br />

ZB5AZ101<br />

ZB5AWO-1<br />

ZB5AW065<br />

MZB5AW035<br />

17-48<br />

Contact Blocks (Mounting Collar with Contact Blocks)<br />

Description<br />

Screw clamp terminal connections<br />

N.O.<br />

1<br />

2<br />

1<br />

1<br />

Type of Contact<br />

N.C.<br />

1<br />

2<br />

1<br />

2<br />

(||jj Telemecanique<br />

<strong>www</strong>.<strong>SquareD</strong>.<strong>com</strong><br />

For the most up-to-date information<br />

Catalog Number<br />

ZB5AZ101<br />

ZB5AZ102<br />

ZB5AZ103<br />

ZB5AZ104<br />

ZB5AZ105<br />

ZB5AZ141<br />

* For Quick-Connect version add "3" to the end of the catalog number Example: ZB5AZ1013 (Quick-Connect size 1 x 0.250' or 2 x 0.110").<br />

* For Ring Tongue <strong>com</strong>patible blocks add "9" to the end of the catalog number (Example: ZB5AZ1029).<br />

» <strong>Electrical</strong> <strong>com</strong>ponents with connection by printed circuit board pins are available. Consult local field office for details.<br />

* <strong>Electrical</strong> <strong>com</strong>ponents with connection by plug-in connector are available. Consult local field office for details.<br />

Complete Bodies (Mounting Collar + Single Contact Block + Light Module with PROTECTED LED®)<br />

Light Source<br />

Type ol Contact<br />

A<br />

N.O. N.C.<br />

Screw clamp terminal connections<br />

^<br />

1<br />

2<br />

1<br />

1<br />

1<br />

Color<br />

White<br />

Green<br />

Red<br />

Yellow<br />

Blue<br />

White<br />

Green<br />

Red<br />

Yellow<br />

Blue<br />

White<br />

Green<br />

Red<br />

Yellow<br />

Blue<br />

White<br />

Green<br />

Red<br />

Yellow<br />

Blue<br />

Supply Voltage<br />

24Vac/dc 110-120 Vac<br />

ZB5AWOB1 1<br />

ZB5AWOB31<br />

ZB5AWOB41<br />

ZB5AWOB51<br />

ZB5AWOB61<br />

ZB5AWOB12<br />

ZB5AWOB32<br />

ZB5AWOB42<br />

ZB5AWOB52<br />

ZB5AWOB62<br />

ZB5AWOB13<br />

ZB5AWOB33<br />

ZB5AWOB43<br />

ZB5AWOB53<br />

ZB5AWOB63<br />

ZB5AWOB15<br />

ZB5AWOB35<br />

ZB5AWOB45<br />

ZB5AWOB55<br />

ZB5AWOB65<br />

Catalog Number<br />

ZB5AWOG11<br />

ZB5AWOG31<br />

ZB5AWOG41<br />

ZB5AWOG51<br />

ZB5AWOG61<br />

ZB5AWOG12<br />

ZB5AWOG32<br />

ZB5AWOG42<br />

ZB5AWOG52<br />

ZB5AWOG62<br />

ZB5AWOG13<br />

ZB5AWOG33<br />

ZB5AWOG43<br />

ZB5AWOG53<br />

ZB5AWOG63<br />

ZB5AWOG15<br />

ZB5AWOG35<br />

ZB5AWOG45<br />

ZB5AWOG55<br />

ZB5AWOG65<br />

Mounting Collar, Contact Block and Light Module (with screw clamp terminal connections) <<br />

Supply Light Source Supply Voltage<br />

Screw clamp terminal connections<br />

irectsuppy<br />

Transformer type<br />

secondary<br />

BA9s<br />

Not included •<br />

BA9s<br />

bulb included<br />

11 0-1 20 Vac<br />

50/60 Hz<br />

230-240 Vac<br />

50/60 Hz<br />

440-480 Vac<br />

60 Hz<br />

. Can be Fitted with additional contact Mocks, see page 17-49.<br />

i Order bulb separately, see page 17-53.<br />

Type of Contact A<br />

N.O. N.C.<br />

1<br />

2<br />

1<br />

Discount<br />

Schedule<br />

1<br />

1<br />

1<br />

1<br />

1<br />

Color of Light<br />

Source<br />

Price<br />

$11.00<br />

11.00<br />

19.10<br />

19.10<br />

19.10<br />

27.30<br />

Price<br />

$36.70<br />

36.70<br />

44.90<br />

44.90<br />

Catalog Number Price<br />

ZB5AW061<br />

ZB5AW062<br />

ZB5AW063<br />

ZB5AW065<br />

ZB5AW031<br />

ZB5AW035<br />

ZB5AW041<br />

ZB5AW045<br />

ZB5AW081<br />

ZB5AW085<br />

$27.40<br />

27.40<br />

35.60<br />

35.60<br />

57.00<br />

65.00<br />

57.00<br />

65.00<br />

57.00<br />

65.00<br />

For additional information, reference Catalog #9001CT0301.<br />

© 2003 Schneider Electric<br />

All Rights Reserved<br />

9/8/03


<strong>Push</strong> <strong>Buttons—XB5</strong> <strong>22</strong> <strong>mm</strong><br />

Characteristics<br />

Environment<br />

Degree of protection<br />

Conforming to standards<br />

Product certifications<br />

Conforming to IEC 529<br />

Conforming to UL 50 and CSA C<strong>22</strong>.2 No. 94<br />

f C Marked<br />

IP65. unless otherwise stated<br />

IP66, for booted push button heads<br />

Type 1, 2, 3, 4, 4X, 12, and 13, unless otherwise stated<br />

IEC 947-1, IEC/EN 60947-5-1, IEC 947-5-4,<br />

EN 60947-1, JISC 4520,<br />

UL508, CSAC<strong>22</strong>.2NO. 14<br />

UL Listed, CSA<br />

® File E1 64353 /S» File LR 44087 •• File E1 64353<br />

Standard single contacts with screw clamp terminals: A600; 0600<br />

Double contacts with screw clamp terminals: A600; Q600<br />

Light modules with screw clamp terminals<br />

CCNNKCR \Jg. Class 321 103 .Yll CCN NKCR 2 JOYSTICK XD4-PA: A600; R300<br />

BV, RINA, LROS, DNV, GL (pending)<br />

Standard single contacts and double contacts with screw clamp terminals<br />

<strong>Electrical</strong> Characteristics of Operators and Contact Blocks<br />

Cabling capacity<br />

Maximum Contact Block<br />

Usage<br />

Rated operational<br />

characteristics<br />

Conforming to<br />

IEC/EN 60947-5-1<br />

<strong>Electrical</strong> durability<br />

Conforming to<br />

IEC/EN 60947-5-1<br />

Appendix C<br />

Operating rate<br />

3600 operating cycles/hour.<br />

Load factor: 0.5<br />

Conforming to IEC 947-1<br />

XB5/ZB5 Maximum Number of Blocks<br />

AC supply:<br />

Utilization category AC-15<br />

DC supply:<br />

Utilization category DC-13<br />

AC supply for 1 million operating cycles,<br />

utilization category AC-15<br />

DC supply for 1 million operating<br />

cycles,<br />

utilization category DC-13<br />

<strong>Electrical</strong> Characteristics of Light Modules<br />

Cabling capacity Conforming to IEC 947-1<br />

Specific Characteristics of PROTECTED LED® Light Modules Only<br />

(Qy Telemecanique<br />

<strong>www</strong>.<strong>SquareD</strong>.<strong>com</strong><br />

For the most up-to-date information<br />

Screw and captive clamp terminals<br />

Min: 1 x 24 AWG 0.<strong>22</strong> <strong>mm</strong> 2 ) without cable end<br />

1 x <strong>22</strong> AWG 0.34 <strong>mm</strong> 2 ) for linking<br />

Max: 2x16 AWG 1 .5 <strong>mm</strong> 2 ) with cable end<br />

2x14 AWG (2.5 <strong>mm</strong> 2 ) without cable ends<br />

Cross headed screw (POZIDRIV type 1 ) slotted for flat 4 and 5.5 <strong>mm</strong> screwdriver<br />

<strong>Push</strong> buttons and selectors (Non-Illuminated)<br />

<strong>Push</strong> buttons and selectors (Illuminated)<br />

Mushrooms, <strong>Push</strong> Pull (Non-Illuminated)<br />

Mushrooms, <strong>Push</strong> Pull (Illuminated)<br />

Mushrooms, Turn-to-Release (Non-Illuminated)<br />

Mushrooms, Trigger Action (Non-Illuminated)<br />

<strong>Push</strong>-on/<strong>Push</strong>-off (Non-Illuminated)<br />

<strong>Push</strong>-on/<strong>Push</strong>-off (Illuminated)<br />

Standard blocks (single or double) with screw clamp terminals:<br />

A600: Ue = 600 Vac and le = 1.2 A or Ue = 240 Vac and le = 3 A<br />

orUe = 120Vacandle = 6A<br />

Continuous Thermal Current 10 A<br />

Standard single or double blocks with screw clamp terminals:<br />

Q600: Ue = 600 Vdc and le = 0.1 A or Ue = 250 Vdc and le = 0.27 A<br />

or Ue = 1 25 Vdc and le = 0.55 A<br />

Joystick XD4PA:<br />

R300: Ue = 1 25 Vdc and le = 0.<strong>22</strong> A or Ue = 250 Vdc and le = 0.1 A<br />

Standard blocks for screw clamp terminals:<br />

24 Vac<br />

4A<br />

120 Vac<br />

3A<br />

Standard double blocks with screw clamp terminals:<br />

24 Vac<br />

3A<br />

120 Vac<br />

1.5 A<br />

Standard single blocks tor screw clamp terminals:<br />

24 Vdc<br />

110Vdc<br />

0.5 A<br />

0.2 A<br />

Standard double blocks with screw clamp terminals:<br />

24 Vdc<br />

0.4 A<br />

110Vdc<br />

0.15A<br />

Screw and captive clamp terminals<br />

Min: 1 x 24 AWG (0.<strong>22</strong> <strong>mm</strong> 2 ) without cable end<br />

1 x <strong>22</strong> AWG (0.34 <strong>mm</strong> 2 ) for linking<br />

Max: 2 x 16 AWG (1.5 <strong>mm</strong> 2 ) wrth cable end<br />

Voltage limits Nominal voltage 24V: 19.2 to 30 Vdc. 21.6 to 24.6 Vac; 120V: 10210 132 Vac: 240V: 195 to 264 Vac<br />

Current consumption Applicable to all colors<br />

Specific Characteristics of Hour Counters and Annunciators<br />

Voltage limits<br />

Current consumption<br />

17-34<br />

Hour counter and annunciator<br />

Hour counter<br />

Annunciator<br />

24 Vac/dc supply blocks: 18mA<br />

120 Vac supply blocks: 14mA<br />

240 Vac supply blocks: 14 mA<br />

± 10% of nominal voltage<br />

XB5DSB:7to15mA<br />

XB5DSG: 8 mA<br />

XB5DSM: 8 mA<br />

5mA<br />

9<br />

6<br />

6<br />

4<br />

6<br />

4<br />

3<br />

2<br />

230 Vac<br />

2A<br />

230 Vac<br />

For additional information, reference Catalog #9001CT0301.<br />

1 A<br />

© 2003 Schneider Electric<br />

All Rights Reserved<br />

9/8/03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!