PROBLEM PART TO CHECK POSSIBLE SOLUTION<br />

Insufficient discharge 1. Suction valve 1. Check that suction inlet ball valve is fully closed<br />

pressure<br />

2. Regulator 2. Pressure regulator could be out of adjustment;<br />

contact a Service Technician at The<br />

Andersons, Systems Equipment Division<br />

Will not discharge 1. Discharge standpipe 1. Check standpipe for blockage; physically remove<br />

obstruction<br />

2. Discharge hose 2. Check hose for blockage; physically remove<br />

obstruction<br />

3. Tank 3. Check for build up of fines and swarf in bottom of<br />

tank; clean as necessary<br />

4. Pneumatic Muffler 4. Ensure pneumatic muffler is not covered by dirt/<br />

/oil; clean or replace<br />

5. Discharge nozzle 5. Check to see if nozzle is plugged, physically<br />

remove obstruction<br />

6. 4 Way Valve 6. Be sure 4 way valve is in discharge position<br />

7. Suction Valve 7. Be sure suction inlet ball valve is fully closed<br />

Fluid dripping from exhaust 1. Float 1A. Ensure that <strong>electric</strong> float is unobstructed and<br />

mufflers operating<br />

1B. Damaged float ball: replace<br />

2. Discharge ports 2. Check that all discharge ports are fully closed<br />

or capped<br />

3. Discharge Nozzle 3. Be sure discharge nozzle is fully closed<br />

4. Tank selector switch 3. On dual <strong>compartment</strong> units, ensure switch is set<br />

for tank in use; improper switch setting will not<br />

enable float switch to work<br />

4. Foam 4. Check for excessive coolant foaming; call coolant<br />

supplier for corrective action<br />

5. Air venturi silencer 5. If fluid drips from air venturi silencer on air units,<br />

check mechanical float assembly for dirt/<br />

particulate around sealing surface of ball<br />