4. As soon as fluid stops passing through the hose, press the STOP button to turn off the<br />

motor. A. The <strong>compartment</strong>’s maximum capacity is, at most, 10% above the rated<br />

capacity. The float switch described in Paragraphs 3 and 4 above, and located near the<br />

<strong>compartment</strong> suction fitting, will shut off the motor if overfilling starts to occur. If this<br />

should happen, follow instructions for the discharge operation in Paragraph 7 below.<br />

5. To return filtered chip-free coolant to the <strong>sump</strong>, or wash down the machine, or<br />

discharge dirty coolant into your recycling or disposal system, close the suction inlet<br />

ball valve. Push the DISCHARGE button and depress the discharge hose nozzle valve.<br />

A. Be sure the suction inlet ball valve is fully closed before operating in the<br />

DISCHARGE mode!<br />

B. IMPORTANT! Be sure the suction inlet ball valve is fully closed or fully open,<br />

depending on the desired operation (closed-discharge, open-suction). Failure to<br />

do so will allow particulates to enter the valve seat and seize the valve.<br />

6. Stop the motor as soon as fluid stops passing through the hose.<br />

A. The cleaner is to be adjusted and/or repaired only by qualified service<br />

personnel. If these personnel need more information than is provided in this<br />

manual, they should contact The Andersons at 419-891-2724<br />

B. The <strong>sump</strong> cleaner will discharge all but about an inch of fluid in the bottom of<br />

the <strong>compartment</strong>. This is unimportant if the <strong>compartment</strong> cleaner is used for one<br />

type of coolant only. If different coolants are to be handled in that <strong>compartment</strong>,<br />

remove its drain plug to empty it completely.<br />

7. To empty the filter basket:<br />

A. Remove tower lid.<br />

B. Attach lifting device to basket rings. CAUTION: All components used to lift<br />

basket (steel cable, hooks, crane, etc.) must have a minimum capacity of 1000<br />

pounds.<br />

C. To avoid the basket binding in the tower during removal, position the lifting<br />

power source (e.g. crane) directly over the center of the basket.<br />