Page 58<br />

Earth Fault by Murray Test<br />

Fig. 20.<br />

When using the Murray Earth fault test on a circuit with a branch or<br />

branches, the following procedure must be observed :<br />

Have lines looped at far end of Main <strong>Circuit</strong> and make test as described<br />

above.<br />

If the earth is on one of the branches, the percentage recorded will give<br />

the junction point of the branch with the main circuit.<br />

The fault may therefore be either at the junction point or on the branch.<br />

The loop should then be removed from the far end of main circuit and<br />

the far end of the branch looped; a further test being made.<br />

The percentage reading obtained will give the approximate location of<br />

the fault by reference to the chart covering the branch concerned.<br />

6. Resistance Measurements by Voltmeter Method. (See Fig. 21).<br />

To measure a resistance other than line resistance, connect resistance to<br />

T1, T3 terminals.