Where satisfactory operation cannot be obtained through a single Repeating<br />

coil, two or more may be connected in series-aiding as shown in Fig. 3.<br />

Branch <strong>Circuit</strong><br />

Intermediate Telegraph Station<br />

Fig. 5.<br />

When it is required to operate selectors on a branch circuit and part of the main<br />

circuit without metallic connection between the two circuits, a transformer connected<br />

as in Fig. 4 may be used between the main circuit and the branch circuit. The capacitor<br />

C is then 10 μF plus 1 μF for each selector on the branch circuit and branch circuit<br />

selector sets have their tuning capacitors short circuited, sets on the main line remaining<br />

normal. Again, if the branch line is too long for satisfactory working through one<br />

transformer or repeating coil, two or more Repeating coils may be connected in<br />

series-aiding.<br />

Page 13