Combustible gas detectors are not usually designed to measure levels of oxygen as they detect<br />

the amount of flammable gas in air of an inert atmosphere. Ideally, a “multi-meter” should be<br />

used when testing for oxygen, hydrocarbons, carbon monoxide and sulphur dioxide.<br />

The atmosphere analysing equipment should be tested first and calibrated in accordance with<br />

manufacturer’s recommendations. Whilst the enclosed space entry is taking place, oxygen<br />

levels should be regularly tested and where appropriate at different height levels to ensure a<br />

safe environment in all areas. Forced ventilation must be stopped during testing.<br />

Figure 3: Testing the atmosphere of the enclosed space<br />

<strong>Enclosed</strong> space entry procedures<br />