Enclosed Space Entry - Shipowners
Enclosed Space Entry - Shipowners
Enclosed Space Entry - Shipowners
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Combustible gas detectors are not usually designed to measure levels of oxygen as they detect<br />
the amount of flammable gas in air of an inert atmosphere. Ideally, a “multi-meter” should be<br />
used when testing for oxygen, hydrocarbons, carbon monoxide and sulphur dioxide.<br />
The atmosphere analysing equipment should be tested first and calibrated in accordance with<br />
manufacturer’s recommendations. Whilst the enclosed space entry is taking place, oxygen<br />
levels should be regularly tested and where appropriate at different height levels to ensure a<br />
safe environment in all areas. Forced ventilation must be stopped during testing.<br />
Figure 3: Testing the atmosphere of the enclosed space<br />
<strong>Enclosed</strong> space entry procedures<br />
7