GloMax ® -Multi Jr Single-Tube Multimode<br />

Reader<br />

Product Size Cat.# Price ($)<br />

GloMax ® -Multi Jr Base Instrument 1 each E6070 Pls. Enq.<br />

GloMax ® -Multi Jr with Luminescence Module 1 each E6080 Pls. Enq.<br />

Fluorescence Optical Kit, Blue (Ex 460nm, Em<br />

515–570nm)<br />

Fluorescence Optical Kit, UV (Ex 365nm, Em<br />

1 each E6071 Pls. Enq.<br />

410–450nm)<br />

Fluorescence Optical Kit, Green (Ex 525nm, Em<br />

1 each E6072 Pls. Enq.<br />

580–640nm)<br />

Fluorescence Optical Kit, Red (Ex 625nm, Em<br />

1 each E6073 Pls. Enq.<br />

660–725nm)<br />

Fluorescence Optical Kit, GFPUV (Ex 365nm, Em<br />

1 each E6074 Pls. Enq.<br />

515–570nm) 1 each E6075 Pls. Enq.<br />

Absorbance Module (User Installable) 1 each E6076 Pls. Enq.<br />

Absorbance Filter Paddle, 560nm 1 each E6077 Pls. Enq.<br />

Absorbance Filter Paddle, 600nm 1 each E6078 Pls. Enq.<br />

Absorbance Filter Paddle, 750nm<br />

Available Separately<br />

GloMax<br />

1 each E6079 Pls. Enq.<br />

® -Multi Jr Reader Luminescence Module<br />

Service Upgrade<br />

Minicell Adapter Kit (for measuring 100–200µl<br />

1 each E6098 Pls. Enq.<br />

of sample) 1 each E6094 Pls. Enq.<br />

PCR Tube Adapter, GloMax ® Multi Jr. 1 each E6081 Pls. Enq.<br />

Minicell Borosilicate Glass Cuvettes<br />

10 × 10mm Square Polystyrene Cuvette (3.5ml<br />

400 each E6091 Pls. Enq.<br />

capacity)<br />

10 × 10mm Square Methacrylate Cuvette (3.5ml<br />

100 each E6092 Pls. Enq.<br />

capacity) 100 each E6093 Pls. Enq.<br />

AC Adapter Replacement<br />

Thermal Serial Printer and Universal Power<br />

1 each E6095 Pls. Enq.<br />

Cable 1 each E2821 Pls. Enq.<br />

Thermal Printer Paper 1 each E2851 Pls. Enq.<br />

GloMax ® -Multi Jr Service Agreement<br />

For Research Use Only. Not for Use in Diagnostic Procedures.<br />

1 each SA3080 Pls. Enq.<br />

Description: The GloMax ® -Multi Jr Single-Tube Multimode Reader is<br />

designed to provide the utmost flexibility. In addition to high performance, the<br />

GloMax ® -Multi Jr blends user-friendly operation and a small footprint with flexible<br />

purchasing options. The result of this design is an instrument with superior<br />

performance that is easy to use, affordable and can be customized to your<br />

laboratory’s needs.<br />

The GloMax ® -Multi Jr with a Luminescence Module is designed to deliver<br />

performance equivalent to dedicated single-tube luminometers while also offering<br />

the flexibility of a multimode reader. The GloMax ® -Multi Jr has a sensitivity<br />

of 1 × 10 –18 moles of luciferase and >5 logs of dynamic range. This dynamic<br />

range is more than adequate to cover common luminescence applications, thus<br />

reducing the need to dilute samples.<br />

For complete and up-to-date product information visit: www.promega.com/catalog<br />

GloMax ® Multi Jr Single-Tube Multimode Reader<br />

The GloMax ® -Multi Jr with a Fluorescence Module is designed to deliver<br />

both high performance and user flexibility. To achieve high performance, each<br />

Fluorescence Module utilizes powerful light-emitting diodes (LEDs) as excitation<br />

sources. LED usage increases sensitivity by fully exciting the fluorophore and<br />

reducing nonspecific light leakage, a problem often found when using broadspectrum<br />

light sources. Four standard fluorescence optical kits are available for<br />

purchase, or contact us to purchase a custom optical kit.<br />

• UV (Ex 365nm, Em 410–450nm)<br />

• Blue (Ex 460nm, Em 515–570nm)<br />

• Green (Ex 525nm, Em 580–640nm)<br />

• Red (Ex 625nm, Em 660–725nm)<br />

The GloMax ® -Multi Jr with the Absorbance Module provides highly sensitive<br />

measurements that cover a wide dynamic range. The absorbance channel<br />

has a large reading range of 0–4 OD with an accuracy that deviates less than<br />

0.7%.<br />

The GloMax ® -Multi Jr has three optional filter paddles with factory-installed filters<br />

for measuring 560, 600 and 750nm. These filters accommodate the most<br />

common protein assays. Filter paddles can be exchanged easily in seconds. In<br />

addition, custom filter paddles can be made readily for nonstandard applications.<br />

The GloMax ® -Multi Jr is designed to use right from the box without the<br />

need to read a manual or obtain special training. To achieve this plug-and-play<br />

usability, the GloMax ® -Multi Jr combines a color touch screen with an intuitive<br />

user interface. The interface makes running samples and viewing data fast and<br />

simple while also maintaining the flexibility needed for advanced or custom<br />

protocols. The GloMax ® -Multi Jr is a modular instrument that fits easily into<br />

most budgets. Purchase the technology or modes that you need now, and add<br />

on to the system later as your needs expand. For example, the GloMax ® -Multi<br />

Jr can be purchased as a Luminometer. Then Fluorescence and/or Absorbance<br />

Modules can be purchased and added later. There’s no service call or downtime.<br />

With the modular design, changing technologies is as easy as snapping in<br />

a module and restarting the instrument.<br />

Features:<br />

• Flexible Configuration: Modular system grows with your needs.<br />

• Touch Screen Interface: The user interface has been designed to be<br />

intuitive so that no training is required to use the instrument.<br />

• Easy Protocol Setup: <strong>Promega</strong> protocols are preloaded for easy implementation.<br />

Protocol Part#<br />

GloMax ® -Multi Jr Operating Manual<br />

TM339<br />

5552TA<br />

189<br />

10<br />

Instruments<br />

Section<br />

Contents<br />

Table of<br />

Contents