Contents<br />

Multimode Readers<br />

186<br />

GloMax ® -Multi+ Detection System with<br />

Instinct Software<br />

Product Size Cat.# Price ($)<br />

GloMax ® -Multi+ Detection System with Instinct<br />

Software: Base Instrument with Shaking 1 each E8032 Pls. Enq.<br />

GloMax ® -Multi+ Detection System with Instinct<br />

Software: Base Instrument with Heating and<br />

Shaking 1 each E9032 Pls. Enq.<br />

GloMax ® -Multi+ Luminescence Module 1 each E8041 Pls. Enq.<br />

GloMax ® -Multi+ Fluorescence Module 1 each E8051 Pls. Enq.<br />

GloMax ® -Multi+ Visible Absorbance Module 1 each E8061 Pls. Enq.<br />

GloMax ® -Multi+ UV-Visible Absorbance Module<br />

Available Separately<br />

1 each E9061 Pls. Enq.<br />

GloMax ® Injector Tips Replacement 1 each E5401 Pls. Enq.<br />

GloMax ® Luminometer Light Plate<br />

Single Injector System for GloMax<br />

1 each E6531 Pls. Enq.<br />

® -Multi Detection<br />

System<br />

Dual Injector System for GloMax<br />

1 each E7071 Pls. Enq.<br />

® -Multi Detection<br />

System 1 each E7081 Pls. Enq.<br />

Cable, USB 2.0 A-B Male 1 each E8072 Pls. Enq.<br />

DB-15 Communication Cable<br />

GloMax<br />

1 each E8081 Pls. Enq.<br />

® -Multi Optical Kit AFC<br />

(also included with Cat.# E7051 or E8051)<br />

GloMax<br />

1 each E8917 Pls. Enq.<br />

® -Multi Optical Kit Blue<br />

(also included with Cat.# E7051 or E8051)<br />

GloMax<br />

1 each E8921 Pls. Enq.<br />

® -Multi Optical Kit UV<br />

(also included with Cat.# E7051 or E8051)<br />

GloMax<br />

1 each E8922 Pls. Enq.<br />

® -Multi Optical Kit Green<br />

(also included with Cat.# E7051 or E8051)<br />

GloMax<br />

1 each E8923 Pls. Enq.<br />

® -Multi Optical Kit Red<br />

(also included with Cat.# E7051 or E8051) 1 each E8924 Pls. Enq.<br />

Injector Inlet Tubing Assembly<br />

Injector Outlet Tubing Assembly for Single-Injector<br />

1 set E8925 Pls. Enq.<br />

System<br />

Injector Outlet Tubing Assembly for Dual-Injector<br />

1 each E8926 Pls. Enq.<br />

System 1 each E8927 Pls. Enq.<br />

Waste Collection Tray<br />

GloMax<br />

1 each E8928 Pls. Enq.<br />

® -Multi Detection System 490nm<br />

Absorbance Filter Set 1 each E8929 Pls. Enq.<br />

USB Flash Drive, 2.0, 2GB<br />

GloMax<br />

1 each E8935 Pls. Enq.<br />

® -Multi+ Detection System Power<br />

Supply—24V, 150W<br />

GloMax<br />

1 each E8942 Pls. Enq.<br />

® -Multi+ Detection System 6-384 Well<br />

Plate Adapter<br />

GloMax<br />

1 each E8943 Pls. Enq.<br />

® -Multi+ Detection System 96 Well Optical<br />

Crosstalk Mask<br />

GloMax<br />

1 each E8944 Pls. Enq.<br />

® -Multi+ Detection System 384 Well Optical<br />

Crosstalk Mask<br />

GloMax<br />

1 each E8945 Pls. Enq.<br />

® -Multi+ Base Instrument Service<br />

Agreement, 1 year 1 each SA3030 Pls. Enq.<br />

GloMax ® Injectors Service Agreement, 1 year<br />

For Research Use Only. Not for Use in Diagnostic Procedures.<br />

1 each SA3040 Pls. Enq.<br />

GloMax ® -Multi+ Detection System with Instinct Software.<br />

Description: The GloMax ® -Multi+ Detection System with Instinct Software<br />

combines the superior performance expected from single-mode instruments<br />

with the functionality of multiple modes. Detection modes include Fluorescence<br />

Intensity, Luminescence and UV-Visible Absorbance. The GloMax ® -Multi+<br />

Detection System accepts 6-, 12-, 24-, 48-, 96- and 384-well plates and<br />

is configured with a factory-installed shaker that allows for either linear or<br />

orbital shaking. The GloMax ® -Multi+ Detection System may be purchased<br />

with an optional heater allowing precise temperature control from 2°C above<br />

ambient temperature to 45°C. The GloMax ® -Multi+ Detection System has a<br />

touch screen interface with an easy-to-use software program. The Instinct<br />

software puts data analysis capabilities on the touch screen. The protocol<br />

composer allows easy development of complex protocols by combining<br />

multiple technologies into one experiment. In addition, a variety of <strong>Promega</strong><br />

and common laboratory protocols are pre-installed. The system works as a<br />

standalone workstation, freeing computing resources from data capture, so<br />

more resources can be directed toward other applications.<br />

The GloMax ® -Multi+ Detection System with Instinct Software is made up<br />

of a base unit available in two different formats, one with shaking (E8032) and<br />

one with heating and shaking (E9032), plus modular detection and functional<br />

units, providing a flexible solution that can be expanded over time. Luminescence,<br />

fluorescence and absorbance reading modules are available as well<br />

as an optional injector system (used with the luminescence detection module<br />

only).<br />

Luminescence Module: An advanced head-on photon-counting photomultiplier<br />

tube (PMT) provides unmatched signal-to-noise ratios, beating most<br />

standalone luminometers. The luminescence module can detect as little as<br />

3 × 10 –21 moles of luciferase, covering a dynamic range over 8 logs. A dualmasking<br />

system minimizes well-to-well cross-talk.<br />

See next page for more information.<br />