2012 Promega catalogue
2012 Promega catalogue
2012 Promega catalogue
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Cell Signaling<br />
GenePrint ® Fluorescent STR Systems<br />
Product Size Cat.# Price ($)<br />
GammaSTR Multiplex (Fluorescein) 100 reactions DC6071 Pls. Enq.<br />
D16S539, D7S820, D13S317, D5S818 400 reactions DC6070 Pls. Enq.<br />
CSF1PO, TPOX, TH01, vWA Multiplex 100 reactions DC6301 Pls. Enq.<br />
(Fluorescein)<br />
Available Separately<br />
400 reactions DC6300 Pls. Enq.<br />
CTTv Allelic Ladder Mix (Fluorescein) 150 µl DG2121 Pls. Enq.<br />
GammaSTR Allelic Ladder Mix (Fluorescein) 150 µl DG3291 Pls. Enq.<br />
DG2121, DG3291 For Research Use Only. Not for Use in Diagnostic Procedures. DC6071,<br />
DC6070, DC6301, DC6300 Not For Medical Diagnostic Use.<br />
Description: The GenePrint ® Fluorescent STR Systems were developed for<br />
use with the Hitachi FMBIO ® Fluorescence Imaging Systems and ABI PRISM ®<br />
377 DNA Sequencer. One primer for each locus is labeled with fluorescein to<br />
allow fluorescent detection. Fluorescein has an excitation maximum at 488nm<br />
and an emission maximum at 532nm. Therefore, the systems are compatible<br />
with a variety of fluorescence-detection instruments, including the ABI PRISM ®<br />
310, 3100 and 3100-Avant Genetic Analyzers and Applied Biosystems 3130<br />
and 3130xl Genetic Analyzers.<br />
Each system provides all materials required to amplify STR regions of purified<br />
genomic DNA except Taq DNA polymerase. Amplification of DNA using the<br />
system components plus Taq DNA polymerase produces fluorescein-labeled<br />
fragments representing alleles from the template DNA. For instruments that<br />
support two-color fluorescence detection, additional precision may be achieved<br />
by including the Internal Lane Standard 600 (Cat.# DG1071) in each gel lane<br />
or injection.<br />
Features:<br />
• High-Throughput Analysis: Analysis is achieved by comparing amplified<br />
DNA fragments directly with the allelic ladder provided for each locus.<br />
• Efficiency: The fluorescent STR multiplex systems support simultaneous<br />
single-tube amplification of four polymorphic STR loci with nonoverlapping<br />
allele size ranges.<br />
• Allelic Ladders: Comparing amplified alleles with allelic ladders provided<br />
with each system allows rapid and reliable allele assignment.<br />
Storage Conditions: Store at –20°C. The fluorescent primer pairs and allelic<br />
ladders are light-sensitive; therefore, minimize light exposure.<br />
Protocol Part#<br />
GenePrint ® Fluorescent STR Systems Technical Manual TMD006<br />
STR Systems<br />
For complete and up-to-date product information visit: www.promega.com/catalog<br />
GenePrint ® STR Systems (Silver Stain<br />
Detection)<br />
Product Size Cat.# Price ($)<br />
GenePrint ® SilverSTR ® III System (D7S820, 100 reactions DC6451 Pls. Enq.<br />
D13S317, D16S539)<br />
400 reactions DC6450 Pls. Enq.<br />
CSF1PO, TPOX, TH01 Multiplex 100 reactions DC6001 Pls. Enq.<br />
400 reactions DC6000 Pls. Enq.<br />
F13A01, FESFPS, vWA Multiplex 100 reactions DC6031 Pls. Enq.<br />
Available Separately<br />
400 reactions DC6030 Pls. Enq.<br />
CTT Allelic Ladder Mix 150 µl DG2101 Pls. Enq.<br />
FFv Allelic Ladder Mix 150 µl DG2141 Pls. Enq.<br />
DG2101, DG2141 For Research Use Only. Not for Use in Diagnostic Procedures. DC6451,<br />
DC6450, DC6001, DC6000, DC6031, DC6030 Not For Medical Diagnostic Use.<br />
Description: The GenePrint ® Silver STR Systems provide a rapid, nonradioactive<br />
method to evaluate small amounts (e.g., 1ng) of human DNA.<br />
The systems provide all materials required to amplify STR regions of purified<br />
genomic DNA except for Taq DNA polymerase and sample DNA. The amplified<br />
STR fragments are separated by polyacrylamide gel electrophoresis and<br />
detected by silver staining.<br />
The combination of SilverSTR ® III, CTT and FFv provides access to seven of<br />
the thirteen core loci that comprise the Combined DNA Index System (CODIS)<br />
database.<br />
Features:<br />
• Economical: The GenePrint ® Silver STR Systems do not require<br />
fluorescence-detection equipment for analysis. The systems are ideal for<br />
labs that are starting STR analysis or do not wish to purchase expensive<br />
fluorescence-detection equipment.<br />
• Efficient: Analysis requires less than one day. Each multiplex allows<br />
simultaneous amplification of three nonoverlapping STR loci for high<br />
discrimination power.<br />
Storage Conditions: Store at –20°C.<br />
Protocol Part#<br />
GenePrint ® STR Systems Technical Manual TMD004<br />
Sex Identification Systems<br />
GenePrint ® Sex Identification Systems<br />
Product Size Cat.# Price ($)<br />
Amelogenin (Fluorescein Detection) 100 reactions DC5171 Pls. Enq.<br />
Amelogenin (TMR)<br />
Not For Medical Diagnostic Use.<br />
100 reactions DC6171 Pls. Enq.<br />
Description: The GenePrint ® Sex Identification Systems can be used for sex<br />
determination. When used under reaction conditions recommended in the<br />
Technical Manuals (#TMD004, #TMD006 and #TMD008), a specific segment of<br />
the human X chromosome generates a 212bp product, while the corresponding<br />
human Y-chromosomal DNA segment produces a 218bp fragment. The Amelogenin<br />
locus may be co-amplified and co-analyzed with a compatible multiplex<br />
system by mixing the Amelogenin primers with those of the appropriate multiplex<br />
system prior to use.<br />
Storage Conditions: Store at –20°C. The fluorescent primer pair and ladder<br />
are light-sensitive; therefore, minimize light exposure.<br />
Protocol Part#<br />
GenePrint ® Fluorescent STR Systems Technical Manual TMD006<br />
PowerPlex ® 1.1 System Technical Manual TMD008<br />
159<br />
7<br />
Genetic Identity<br />
Section<br />
Contents<br />
Table of<br />
Contents