13.03.2013 Views

2012 Promega catalogue

2012 Promega catalogue

2012 Promega catalogue

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Life<br />

Science<br />

Catalog<br />

<strong>2012</strong><br />

Worldwide Contact List<br />

Section<br />

Contents<br />

Table of<br />

Contents<br />

Cell Signaling<br />

154<br />

PowerPlex ® 16 HS System<br />

Product Size Cat.# Price ($)<br />

PowerPlex ® 16 HS System 100 reactions DC2101 Pls. Enq.<br />

400 reactions DC2100 Pls. Enq.<br />

Available Separately Size Conc. Cat. # Price ($)<br />

Internal Lane Standard 600 150 µl DG1071 354.00<br />

9947A DNA 250 ng 10 ng/µl DD1001 194.00<br />

Water, Amplification Grade 6,250 µl DW0991 Pls. Enq.<br />

DG1071, DW0991 For Laboratory Use. DC2101, DC2100, DD1001 Not For Medical Diagnostic<br />

Use.<br />

Description: The PowerPlex ® 16 HS System is a multiplex STR system for<br />

use in DNA typing. This system co-amplifies the loci D18S51, D21S11, TH01,<br />

D3S1358, Penta E (labeled with fluorescein); FGA, TPOX, D8S1179, vWA and<br />

Amelogenin (labeled with TMR); and CSF1PO, D16S539, D7S820, D13S317,<br />

D5S818 and Penta D (labeled with JOE). This multiplex includes all 13 CODIS<br />

STR markers, Amelogenin for gender determination and two low-stutter, highly<br />

discriminating pentanucleotide STR markers. All sixteen loci are amplified simultaneously<br />

in a single tube and analyzed in a single injection. The PowerPlex ®<br />

16 HS System is compatible with ABI PRISM ® 310, 3100 and 3100-Avant<br />

Genetic Analyzers and Applied Biosystems 3130, 3130xl, 3500 and 3500xL<br />

Genetic Analyzers.<br />

Features:<br />

• Robustness: The PowerPlex ® 16 HS System is more tolerant of PCR<br />

inhibitors than competing STR systems and the previous version of<br />

PowerPlex ® 16. Generate profiles with samples that previously failed to<br />

amplify. Avoid costly and time-consuming sample cleanup.<br />

• Sensitivity: Each lot is quality tested to produce full profiles from 100pg<br />

of DNA. Gain confidence in analysis of limited samples.<br />

• High Discrimination: The loci included in the PowerPlex ® 16 HS System<br />

are more discriminating than competitive systems and are ideal for resolving<br />

partial matches or challenging familial cases.<br />

• Proven Design: Primer sequences, dyes and ladders are all unchanged<br />

from PowerPlex ® 16. Expect concordance with existing databases.<br />

• Complete System: The PowerPlex ® 16 HS System includes size standard,<br />

amplification-grade water and Taq DNA polymerase in the master mix.<br />

Simple to order, easy to use.<br />

• Automatic Assignment of Genotypes: Panels and bins text files are<br />

required for automatic assignment of genotypes using the GeneMapper ®<br />

ID and ID-X software and are available for download.<br />

Storage Conditions: Store at –20°C.<br />

Protocol Part#<br />

PowerPlex ® 16 HS System Technical Manual TMD022<br />

PowerPlex ® 16 System<br />

Product Size Cat.# Price ($)<br />

PowerPlex ® 16 System 100 reactions DC6531 Pls. Enq.<br />

400 reactions DC6530 Pls. Enq.<br />

Available Separately Size Conc. Cat. # Price ($)<br />

Internal Lane Standard 600 150 µl DG1071 354.00<br />

9947A DNA 250 ng 10 ng/µl DD1001 194.00<br />

DG1071 For Laboratory Use. DC6531, DC6530, DD1001 Not For Medical Diagnostic Use.<br />

Description: The PowerPlex ® 16 System is a multiplex STR system for use in<br />

DNA typing, including paternity testing, forensic DNA analysis, human identity<br />

testing and tissue culture strain identification. The system allows co-amplification<br />

and three-color detection of sixteen loci (fifteen STR loci and Amelogenin):<br />

Penta E, D18S51, D21S11, TH01, D3S1358, FGA, TPOX, D8S1179, vWA, Amelogenin,<br />

Penta D, CSF1PO, D16S539, D7S820, D13S317 and D5S818. One<br />

primer for each of the Penta E, D18S51, D21S11, TH01 and D3S1358 loci is<br />

labeled with fluorescein (FL); one primer for each of the FGA, TPOX, D8S1179,<br />

vWA and Amelogenin loci is labeled with carboxy-tetramethylrhodamine<br />

(TMR); and one primer for each of the Penta D, CSF1PO, D16S539, D7S820,<br />

D13S317 and D5S818 loci is labeled with 6-carboxy-4´,5´-dichloro-2´,7´dimethoxy-fluorescein<br />

(JOE). All sixteen loci are amplified simultaneously in a<br />

single tube and analyzed in a single injection or gel lane.<br />

The PowerPlex ® 16 System is compatible with the ABI PRISM ® 310, 3100 and<br />

3100-Avant Genetic Analyzers, Applied Biosystems 3130 and 3130xl Genetic<br />

Analyzers and ABI PRISM ® 377 DNA Sequencer.<br />

Features:<br />

• Single Amplification: Amplify all 13 CODIS STR loci in one reaction.<br />

• Maximum Sensitivity: Analyze minute quantities of DNA. The system<br />

is optimized for use with 1ng of DNA; however, each lot is performance<br />

tested to provide reproducible results with 0.5ng of DNA. Additional studies<br />

show interpretable results can be obtained with