<strong>MGC</strong> Release Notes - Version 7.5<br />
Connecting to an MCU<br />
74<br />
Before running the diagnostic tests on an MCU, you must connect the MCU to the Falcon<br />
diagnostic tool.<br />
To connect the Falcon diagnostic tool to a specific MCU:<br />
1. Double-click on the selected MCU icon or right-click on the MCU icon and click<br />
Connect from the right mouse menu or the Main menu options.<br />
A message appears indicating that the MCU must be reset in the Falcon mode.<br />
2. Click OK.<br />
You must close all On Going Conferences before opening the Falcon diagnostic<br />
tool. If a conference is running when you try to connect to an MCU, an error<br />
message is displayed indicating that you must first close the On Going<br />
Conference.<br />
When the Falcon diagnostic tool resets the MCU, it identifies the MCU cards that can be<br />
tested. Cards that cannot be tested are displayed in the <strong>MGC</strong> Manager but not in the Falcon<br />
tool.