Table 8: Diagnostic Tests<br />
Card Unit Test Description<br />
Appendix A - Falcon Diagnostic Tool<br />
Video+ CM PCI Scans the PCI to ensure that its<br />
components are working<br />
properly.<br />
Memory Checks buses’ data and<br />
addresses.<br />
Checks memory integrity and<br />
capacity.<br />
TDM Creates a loop between the DSP<br />
through the backplane and the<br />
BCOD then back to the DSP via<br />
the time slot switch to check data<br />
transfer through the loop.<br />
BCOD Checks the H-sync and F-sync<br />
clocks and BCOD memory.<br />
Proc Memory Checks buses’ data and<br />
addresses.<br />
Checks free memory.<br />
Clock Checks the frequency rate of the<br />
processor.<br />
MCU Level Tests<br />
When the Falcon diagnostic tool is run at the MCU level, all available tests are run on all<br />
the recognized cards installed on that MCU and their units. Several MCUs can be tested<br />
simultaneously, and their tests run serially.<br />
Card Level Tests<br />
When the Falcon diagnostic tool runs tests on an installed recognized card, it performs all<br />
the available tests on all the card’s component units. You can test all cards of a certain type,<br />
for example, all the Video+ cards. All tests run on the Falcon diagnostics tool are run<br />
serially rather than simultaneously.<br />
Unit Level Tests<br />
At the unit level, tests can be selected individually. A specific test, for example, the TDM<br />
test, can be run on all cards installed on the MCU as long as each test is initiated<br />
individually. The tests run serially.<br />