MGC-25/50/100 MGC+50/100 - Polycom
MGC-25/50/100 MGC+50/100 - Polycom
MGC-25/50/100 MGC+50/100 - Polycom
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Table 6: Pending Issues (Continued)<br />
24. ISDN After upgrade to version 7.5, the MCU<br />
loses the ISDN clock source<br />
configuration. In Faults file there is no<br />
message about “NO CLOCK<br />
SOURCE”.<br />
<strong>25</strong>. ISDN ISDN endpoints fail to move to Video<br />
Switching conference when the line<br />
rate of the destination conference is<br />
higher then the line rate at the initial<br />
conference.<br />
Corrections, Pending Issues and Limitations<br />
#. Category Description ID# Remarks<br />
26. IP+ In a mixed system with ISDN and IP,<br />
when the clock is set to ISDN and you<br />
set the source of the ISDN span to Null,<br />
the IP+ card may stop responding.<br />
27. IP+ After participants disconnect from a<br />
conference, the LED on the card is still<br />
On (Active).<br />
28. IPower IPower fails to send content in a CP<br />
conference set to Auto, H.239 P+C and<br />
dial out.<br />
29. <strong>MGC</strong> Manager In the H.245 Properties dialog box,<br />
when H.239 is used, P+C is indicated<br />
instead.<br />
30. <strong>MGC</strong> Manager Wrong indication in the <strong>MGC</strong> Manager<br />
when Moving IP endpoints from one<br />
Video Switching 384 Kbps to a Video<br />
Switching 512 Kbps conference, the<br />
participant appears connected when<br />
they should say secondary.<br />
31. <strong>MGC</strong> Manager On an XPEK MCU, when extreme<br />
packet loss occurs, the <strong>MGC</strong> Manager<br />
can loose connection with the MCU.<br />
32. <strong>MGC</strong>-<strong>25</strong> The Resource Report does not display<br />
IP capacities for line rates of <strong>25</strong>6 Kbps<br />
and 512 Kbps.<br />
33. <strong>MGC</strong>-<strong>25</strong> Moving 3 IP participants from CP Quad<br />
View to a CP COP Quad View<br />
conference fails on the <strong>MGC</strong><strong>25</strong>.<br />
34. MUX When an undefined ISDN participant<br />
connects to a CP conference using a<br />
lower rate than the conference, the call<br />
is rejected. Other endpoints are unable<br />
to connect.<br />
20685 Reconfigure the<br />
ISDN clock.<br />
20932<br />
— Set the<br />
system.cfg<br />
(MCU_CLOCKING<br />
section) flag:<br />
INTERNAL_CLOCK<br />
= YES prior to<br />
setting the ISDN<br />
span to Null.<br />
17890<br />
21066<br />
20468<br />
20933<br />
21519<br />
18307<br />
20926 Move<br />
participants one<br />
at a time.<br />
20166<br />
51