<strong>MGC</strong> Release Notes - Version 7.5<br />
28<br />
To enable a Mandatory and Secure connection for the MCU:<br />
1. Before connecting the MCU, right-click the MCU icon and click MCU Utils, then<br />
click Edit “system.cfg”.<br />
The SysConfig dialog box opens.<br />
2. In the GENERAL section, set the following flags to:<br />
— SECURED_PORT_MANDATORY_FOR_API=YES<br />
— SECURED_PORT_MANDATORY_FOR_FILE=YES<br />
— PREFERRED_SECURED_PORT=443<br />
3. Click OK and then reset the MCU.<br />
4. Right-click the MCU icon and then click Properties.<br />
Do not connect to the MCU. When you right-click the MCU, the MCU should be<br />
disconnected and the icon appear grey.<br />
5.<br />
The Properties dialog box opens.<br />
Click Advanced.<br />
6. Select the Secured check box to enable mandatory security.<br />
7. Ensure that the Automatic Discovery option is deactivated (clear the check box).<br />
8. The Port Number box is enabled, enter port 443 as the Port Number.<br />
9. Click OK.<br />
10. Connect to the MCU.<br />
When reconnected, the MCU uses the secured port.<br />
After reconnecting, it is recommended to change the login password.