Chapter 12 Logging and Severities for Expert Alarms 262 Sniffer Portable Professional Expert alarms (symptoms and diagnoses) can be assigned one of five different severity levels: Critical/Diag, Major, Minor, Warning, and Informational. The severity level for a symptom or diagnosis displays in the summary pane of the Expert window. It is also recorded in the Alarm log if the alarm setting Alarm Logged is set to YES in the Tools > Expert Options > Alarms tab. IMPORTANT: Alarms (both Monitor and Expert) are only logged in the Monitor > Alarm Log if the Enable Alarm option is checked in the Tools > Options > Alarm tab. This option is enabled by default. See Setting Up Logging for the Local Alarm Log on page 259 for details. To change the severity level for an Expert alarm, select Expert Options from the Tools menu and click the Alarms tab (Figure 12-4). Then, click (0) or (1) at the top of the left column to expand/collapse all Expert layers. Click (+) or (-) next to an Expert layer to display all alarms for that level. For the Alarm log to record the alarm, you must set the Alarm Logged option to Yes. Click in the Value cell for an alarm to display a dropdown box. From the dropdown box, select a severity level. NOTE: The alarm must be recorded in the Alarm log for notification to take place. Refer to Setting an Alarm Notification Action on page 265.

Click the + to open an Expert layer and display all alarms Click the + to display an alarm’s settings Alarm Logged must be set to Yes to record the alarm in the Alarm log. Click to expand/collapse all Expert layers Figure 12-4. Setting Severity Levels for Expert Alarms Managing Alarms Click the Value cell for the severity to display the drop-down box. User’s Guide 263

Chapter 12<br />

Logging and Severities for Expert Alarms<br />

262 Sniffer <strong>Portable</strong> <strong>Professional</strong><br />

Expert alarms (symptoms and diagnoses) can be assigned one of five<br />

different severity levels: Critical/Diag, Major, Minor, Warning, and<br />

Informational. The severity level for a symptom or diagnosis displays in<br />

the summary pane of the Expert window. It is also recorded in the Alarm<br />

log if the alarm setting Alarm Logged is set to YES in the Tools ><br />

Expert Options > Alarms tab.<br />

IMPORTANT: Alarms (both Monitor and Expert) are only logged in the<br />

Monitor > Alarm Log if the Enable Alarm option is checked in the<br />

Tools > Options > Alarm tab. This option is enabled by default. See<br />

Setting Up Logging for the Local Alarm Log on page 259 for details.<br />

To change the severity level for an Expert alarm, select Expert Options<br />

from the Tools menu and click the Alarms tab (Figure 12-4). Then, click<br />

(0) or (1) at the top of the left column to expand/collapse all Expert<br />

layers. Click (+) or (-) next to an Expert layer to display all alarms for<br />

that level. For the Alarm log to record the alarm, you must set the Alarm<br />

Logged option to Yes.<br />

Click in the Value cell for an alarm to display a dropdown box. From the<br />

dropdown box, select a severity level.<br />

NOTE: The alarm must be recorded in the Alarm log for notification<br />

to take place. Refer to Setting an Alarm Notification Action on page<br />

265.