10.03.2013 Views

Sniffer® Portable Professional User's Guide - NetScout

Sniffer® Portable Professional User's Guide - NetScout

Sniffer® Portable Professional User's Guide - NetScout

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

This picture<br />

graphically<br />

depicts your<br />

trigger<br />

definition<br />

To define a trigger:<br />

1 Select Trigger Setup from the Capture menu.<br />

Defining Filters and Triggers<br />

The Trigger Setup dialog box opens (shown in Figure 10-8).<br />

Click to specify which events to use<br />

as a start trigger (start time and date,<br />

threshold alarm, and/or event filter)<br />

Define how to control packet capture:<br />

Start trigger, stop trigger, delay after<br />

trigger, or repeat mode<br />

Figure 10-8. Defining a Trigger<br />

Specify what capture<br />

filter to use when the<br />

trigger event occurs<br />

Click to specify which events to use<br />

as a stop trigger (start time and date,<br />

threshold alarm, and/or event filter)<br />

2 Select Enable under Start Trigger, Stop Trigger, or both. Start<br />

triggers start capture sessions when the trigger event is detected.<br />

Stop triggers stop a capture session when the trigger event is<br />

detected. Start and stop triggers do both.<br />

3 Click the Define button corresponding to the type of trigger event<br />

you want to specify (Start or Stop).<br />

Either the Start Trigger dialog box (Figure 10-9) or the Stop Trigger<br />

dialog box appears, depending on which Define button you clicked.<br />

These dialog boxes let you specify the Start or Stop Trigger event.<br />

Existing trigger profiles are shown in the Triggers list.<br />

User’s <strong>Guide</strong> 243