Sniffer® Portable Professional User's Guide - NetScout

Sniffer® Portable Professional User's Guide - NetScout Sniffer® Portable Professional User's Guide - NetScout

10.03.2013 Views

Chapter 5 106 Sniffer Portable Professional The Rsp Time value specifies at what point a response using the specified protocol is considered “slow.” For example, if Rsp Time were set to 5000 milliseconds for HTTP, any response to an HTTP request that took longer than 5000 milliseconds would be considered “slow.” When the percentage of “slow” responses on a given Server-Client connection exceeds the % Applied threshold (see below), the Monitor generates an alarm on the connection. The % Applied value specifies the maximum acceptable percentage of responses exceeding the Rsp Time threshold on a given connection using the specified protocol. When the percentage of connections exceeding the Rsp Time threshold on a given Server-Client connection exceeds the % Applied threshold, the Monitor generates an alarm on the connection. Generated alarms are written to the alarm log. Actions take place as a result of generated alarms according to the options you have set on the Alarms tab of the Options dialog box. See Managing Alarms on page 257 for details. The following example shows the ART application window in the tabular view along with descriptions of its toolbar items.

Tabular view Server Only bar chart Refresh display Click to display application response times for different protocols. The protocols available depend on the options you have enabled in the Display Protocols tab of the ART Options dialog box. Reset display Monitoring Your Network Server-Client Response Time bar chart Properties Set refresh interval Set display options for bar charts Specify display protocols Figure 5-9. The ART Display (Tabular View) and Toolbar User’s Guide 107

Tabular view<br />

Server Only bar chart<br />

Refresh display<br />

Click to display application response times for<br />

different protocols. The protocols available depend on<br />

the options you have enabled in the Display Protocols<br />

tab of the ART Options dialog box.<br />

Reset display<br />

Monitoring Your Network<br />

Server-Client Response Time bar chart<br />

Properties<br />

Set refresh interval<br />

Set display options for bar charts<br />

Specify display protocols<br />

Figure 5-9. The ART Display (Tabular View) and Toolbar<br />

User’s <strong>Guide</strong> 107

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!