Sniffer Adaptive Application Analyzer: Adaptive Mode ... - NetScout
Sniffer Adaptive Application Analyzer: Adaptive Mode ... - NetScout Sniffer Adaptive Application Analyzer: Adaptive Mode ... - NetScout
EARLY FIELD TRIAL Chapter 4 Multicast Groups 92 Sniffer Adaptive Application Analyzer The Multicast Groups tab (a) displays the multicast source and destination addressing that are most active on the network in the Top N Multicast Groups report. Select data in the Statistics panel, then right-click the Graph panel and choose Chart selections only to update the report values. The items checked in the Statistics panel are now displayed in the chart. Deselect Chart selections only to toggle back to the default values. Modify the chart’s data time window by changing the selection in the Time Selection drop down list (b). Using a different time selection will dynamically update the chart. Send the output to your printer using the button at the right of the Graph panel. b a Figure 4-17. Multicast Groups Tab You can also create new Reports tabs including just those fields in which you are interested. See Modifying Statistics Panel Columns and Tabs on page 104.
EARLY FIELD TRIAL Working with the Statistics Panel Using the Statistics Panel This section describes how to perform different tasks in the Statistics panel, including how to set Statistics Filters, work with the Top N feature, and so on. It includes the following topics: Using Statistics Filtering on page 93 Refreshing Statistics on page 97 Selecting and Deselecting Rows on page 97 Sorting Statistics Panel Tabs on page 98 Using the Statistics Panel Tools on page 99 Using Statistics Filtering The Statistics Filtering features are found below the Statistics panel (Figure 4-18). These features let you limit the data displayed in the Statistics panel. Sniffer Adaptive Application Analyzer includes the following Statistics Filtering features: Statistics Filter – Lets you select any currently defined Mining Filter and apply it as a Statistics filter. See Selecting a Statistics Filter on page 94. NOTE: Filters with a Pattern Match component cannot be used as Statistics filters. An error message will appear if you attempt to select such a filter. Top N (approx.) – Lets you limit the number of conversation records displayed. The Console will only display the Top N conversation records in each of the time buckets required to satisfy the current Graph panel selection. See Working with the Top N Feature on page 95. Figure 4-18. Statistics Filtering Options Statistics Filters versus Top N The Statistics Filters and Top N features serve different, complementary purposes: User’s Guide 93
- Page 41 and 42: EARLY FIELD TRIAL Table 2-1. Postca
- Page 43 and 44: EARLY FIELD TRIAL SECTION 2 Getting
- Page 45 and 46: EARLY FIELD TRIAL Working with the
- Page 47 and 48: EARLY FIELD TRIAL Introducing the N
- Page 49 and 50: EARLY FIELD TRIAL Other Navigation
- Page 51 and 52: EARLY FIELD TRIAL Using the Time Se
- Page 53 and 54: EARLY FIELD TRIAL Working with the
- Page 55 and 56: EARLY FIELD TRIAL Zoom Menu Working
- Page 57 and 58: EARLY FIELD TRIAL Introducing the G
- Page 59 and 60: EARLY FIELD TRIAL Selected Statisti
- Page 61 and 62: EARLY FIELD TRIAL Pie Chart Working
- Page 63 and 64: EARLY FIELD TRIAL Column Chart Work
- Page 65 and 66: EARLY FIELD TRIAL Time Series Chart
- Page 67 and 68: EARLY FIELD TRIAL Working with the
- Page 69 and 70: EARLY FIELD TRIAL Working with the
- Page 71 and 72: EARLY FIELD TRIAL Using the Statist
- Page 73 and 74: EARLY FIELD TRIAL Summary Tab a Usi
- Page 75 and 76: EARLY FIELD TRIAL Using the Statist
- Page 77 and 78: EARLY FIELD TRIAL Port Tab Using th
- Page 79 and 80: EARLY FIELD TRIAL Network Tab Using
- Page 81 and 82: EARLY FIELD TRIAL Destination Tab U
- Page 83 and 84: EARLY FIELD TRIAL Using the Statist
- Page 85 and 86: EARLY FIELD TRIAL VLAN ID Tab Using
- Page 87 and 88: EARLY FIELD TRIAL Reports Tabs Usi
- Page 89 and 90: EARLY FIELD TRIAL Top Conversations
- Page 91: EARLY FIELD TRIAL Multicast Protoco
- Page 95 and 96: EARLY FIELD TRIAL Using the Statist
- Page 97 and 98: EARLY FIELD TRIAL Refreshing Statis
- Page 99 and 100: EARLY FIELD TRIAL Using the Statist
- Page 101 and 102: EARLY FIELD TRIAL Showing and Hidin
- Page 103 and 104: EARLY FIELD TRIAL Resolving DNS Nam
- Page 105 and 106: EARLY FIELD TRIAL Table 4-1. New Co
- Page 107 and 108: EARLY FIELD TRIAL SECTION 2 Capturi
- Page 109 and 110: EARLY FIELD TRIAL Capturing and Min
- Page 111 and 112: EARLY FIELD TRIAL Configuring and S
- Page 113 and 114: EARLY FIELD TRIAL Capture Mode Adap
- Page 115 and 116: EARLY FIELD TRIAL Mining Packet Dat
- Page 117 and 118: EARLY FIELD TRIAL Capturing and Min
- Page 119 and 120: EARLY FIELD TRIAL Using Filters in
- Page 121 and 122: EARLY FIELD TRIAL Reusable Filters
- Page 123 and 124: EARLY FIELD TRIAL Figure 6-2. Apply
- Page 125 and 126: EARLY FIELD TRIAL Working with Auto
- Page 127 and 128: EARLY FIELD TRIAL Table 6-3. Filter
- Page 129 and 130: EARLY FIELD TRIAL Using Filters in
- Page 131 and 132: EARLY FIELD TRIAL Using Pattern Mat
- Page 133 and 134: EARLY FIELD TRIAL Applying Mining F
- Page 135 and 136: EARLY FIELD TRIAL Using Filters in
- Page 137 and 138: EARLY FIELD TRIAL Adaptive Display
- Page 139 and 140: EARLY FIELD TRIAL SECTION 3 Analyzi
- Page 141 and 142: EARLY FIELD TRIAL Adaptive Session
EARLY FIELD TRIAL Chapter 4<br />
Multicast Groups<br />
<br />
92 <strong>Sniffer</strong> <strong>Adaptive</strong> <strong>Application</strong> <strong>Analyzer</strong><br />
The Multicast Groups tab (a) displays the multicast source and<br />
destination addressing that are most active on the network in the Top N<br />
Multicast Groups report.<br />
Select data in the Statistics panel, then right-click the Graph panel and<br />
choose Chart selections only to update the report values. The items<br />
checked in the Statistics panel are now displayed in the chart. Deselect<br />
Chart selections only to toggle back to the default values.<br />
Modify the chart’s data time window by changing the selection in the<br />
Time Selection drop down list (b). Using a different time selection will<br />
dynamically update the chart. Send the output to your printer using the<br />
button at the right of the Graph panel.<br />
b a<br />
Figure 4-17. Multicast Groups Tab<br />
You can also create new Reports tabs including just those fields in which<br />
you are interested. See Modifying Statistics Panel Columns and Tabs on<br />
page 104.