Sniffer Adaptive Application Analyzer: Adaptive Mode ... - NetScout
Sniffer Adaptive Application Analyzer: Adaptive Mode ... - NetScout Sniffer Adaptive Application Analyzer: Adaptive Mode ... - NetScout
EARLY FIELD TRIAL Chapter 3 Figure 3-9. Selected Statistics Tab 60 Sniffer Adaptive Application Analyzer a b
EARLY FIELD TRIAL Pie Chart Working with the Quick Select Window The Pie Chart tab displays data statistics from the Statistics panel. It displays the first N entries in the active Statistics panel tab, by default. The entries are sorted according to the current sort order in place in the active Statistics panel tab. If no sort order is in place, the entries are sorted by order of the leftmost column in the active Statistics panel tab. IMPORTANT: The Pie Chart tab requires at least one Statistics panel column (for example, Bytes) to draw a chart. Charting Selected Data You can also display the Pie Chart using only data from selected entries. To do this, select entries in the Statistics panel, then right-click the Graph panel and choose Chart selections only to update the Pie Chart values. The items checked in the Statistics panel (a) are now displayed in the Pie Chart (b). Deselect Chart selections only to toggle back to the default values. NOTE: You can select up to 15 items when Chart selections only is enabled. In the figure, the selected data statistics are displayed in the Graph panel’s pie chart. You can click on one of the Statistics tab’s column headers to change the sorted statistic or sort order and modify the pie chart accordingly. Send the output to your printer using the button at the right of the Graph panel. NOTE: Because the Pie Chart tab truncates percentage values to a tenth of a percent, the percentage values shown in the pie chart legend will occasionally not sum exactly to the Total: 100% shown in the display. The true values do always sum to 100%, but the Console must truncate them to a tenth of a percent for display purposes. Choose another Statistics panel tab to view a different report. See Viewing Reports on the Spreadsheet Tab on page 67 for a list of available reports. User’s Guide 61
- Page 9 and 10: EARLY FIELD TRIAL Contents Setting
- Page 11 and 12: EARLY FIELD TRIAL SECTION 1 Introdu
- Page 13 and 14: EARLY FIELD TRIAL Sniffer Adaptive
- Page 15 and 16: EARLY FIELD TRIAL Figure 1-2. Adapt
- Page 17 and 18: EARLY FIELD TRIAL Sniffer Adaptive
- Page 19 and 20: EARLY FIELD TRIAL Sample Trace File
- Page 21 and 22: EARLY FIELD TRIAL Sniffer Adaptive
- Page 23 and 24: EARLY FIELD TRIAL Key Terms Table 1
- Page 25 and 26: EARLY FIELD TRIAL Table 1-3. Key Te
- Page 27 and 28: EARLY FIELD TRIAL Quick Start - Fiv
- Page 29 and 30: EARLY FIELD TRIAL Double-click the
- Page 31 and 32: EARLY FIELD TRIAL Quick Start - Fiv
- Page 33 and 34: EARLY FIELD TRIAL Step 4 - Capturin
- Page 35 and 36: EARLY FIELD TRIAL Capture Mode Adap
- Page 37 and 38: EARLY FIELD TRIAL Step 5 - Mining P
- Page 39 and 40: EARLY FIELD TRIAL Adaptive Postcapt
- Page 41 and 42: EARLY FIELD TRIAL Table 2-1. Postca
- Page 43 and 44: EARLY FIELD TRIAL SECTION 2 Getting
- Page 45 and 46: EARLY FIELD TRIAL Working with the
- Page 47 and 48: EARLY FIELD TRIAL Introducing the N
- Page 49 and 50: EARLY FIELD TRIAL Other Navigation
- Page 51 and 52: EARLY FIELD TRIAL Using the Time Se
- Page 53 and 54: EARLY FIELD TRIAL Working with the
- Page 55 and 56: EARLY FIELD TRIAL Zoom Menu Working
- Page 57 and 58: EARLY FIELD TRIAL Introducing the G
- Page 59: EARLY FIELD TRIAL Selected Statisti
- Page 63 and 64: EARLY FIELD TRIAL Column Chart Work
- Page 65 and 66: EARLY FIELD TRIAL Time Series Chart
- Page 67 and 68: EARLY FIELD TRIAL Working with the
- Page 69 and 70: EARLY FIELD TRIAL Working with the
- Page 71 and 72: EARLY FIELD TRIAL Using the Statist
- Page 73 and 74: EARLY FIELD TRIAL Summary Tab a Usi
- Page 75 and 76: EARLY FIELD TRIAL Using the Statist
- Page 77 and 78: EARLY FIELD TRIAL Port Tab Using th
- Page 79 and 80: EARLY FIELD TRIAL Network Tab Using
- Page 81 and 82: EARLY FIELD TRIAL Destination Tab U
- Page 83 and 84: EARLY FIELD TRIAL Using the Statist
- Page 85 and 86: EARLY FIELD TRIAL VLAN ID Tab Using
- Page 87 and 88: EARLY FIELD TRIAL Reports Tabs Usi
- Page 89 and 90: EARLY FIELD TRIAL Top Conversations
- Page 91 and 92: EARLY FIELD TRIAL Multicast Protoco
- Page 93 and 94: EARLY FIELD TRIAL Working with the
- Page 95 and 96: EARLY FIELD TRIAL Using the Statist
- Page 97 and 98: EARLY FIELD TRIAL Refreshing Statis
- Page 99 and 100: EARLY FIELD TRIAL Using the Statist
- Page 101 and 102: EARLY FIELD TRIAL Showing and Hidin
- Page 103 and 104: EARLY FIELD TRIAL Resolving DNS Nam
- Page 105 and 106: EARLY FIELD TRIAL Table 4-1. New Co
- Page 107 and 108: EARLY FIELD TRIAL SECTION 2 Capturi
- Page 109 and 110: EARLY FIELD TRIAL Capturing and Min
EARLY FIELD TRIAL<br />
Pie Chart<br />
Working with the Quick Select Window<br />
The Pie Chart tab displays data statistics from the Statistics panel. It<br />
displays the first N entries in the active Statistics panel tab, by default.<br />
The entries are sorted according to the current sort order in place in the<br />
active Statistics panel tab. If no sort order is in place, the entries are<br />
sorted by order of the leftmost column in the active Statistics panel tab.<br />
IMPORTANT: The Pie Chart tab requires at least one Statistics panel<br />
column (for example, Bytes) to draw a chart.<br />
Charting Selected Data<br />
You can also display the Pie Chart using only data from selected entries.<br />
To do this, select entries in the Statistics panel, then right-click the<br />
Graph panel and choose Chart selections only to update the Pie Chart<br />
values. The items checked in the Statistics panel (a) are now displayed<br />
in the Pie Chart (b). Deselect Chart selections only to toggle back to<br />
the default values.<br />
NOTE: You can select up to 15 items when Chart selections only is<br />
enabled.<br />
In the figure, the selected data statistics are displayed in the Graph<br />
panel’s pie chart. You can click on one of the Statistics tab’s column<br />
headers to change the sorted statistic or sort order and modify the pie<br />
chart accordingly.<br />
Send the output to your printer using the button at the right of the Graph<br />
panel.<br />
NOTE: Because the Pie Chart tab truncates percentage values to a<br />
tenth of a percent, the percentage values shown in the pie chart<br />
legend will occasionally not sum exactly to the Total: 100% shown<br />
in the display. The true values do always sum to 100%, but the<br />
Console must truncate them to a tenth of a percent for display<br />
purposes.<br />
Choose another Statistics panel tab to view a different report. See<br />
Viewing Reports on the Spreadsheet Tab on page 67 for a list of available<br />
reports.<br />
User’s Guide 61