Taking the bulk density pos = 0.475 g/cm 3 into account, the specific mass flow rate becomes<br />

The feed angle 0 is required to calculate the actual flow rate. With the assumptions already<br />

made and assuming equal friction coefficients on screw/s and barrel^,, the approximate<br />

feed angle may be calculated from [6]<br />

where<br />

With/S =fh - 0.25 and the average diameter<br />

D 3 492<br />

With K = 0.522 and —<strong>•</strong>*- = — = 0.6906 we obtain from Equation 5.26<br />

5.057<br />

Db<br />

Inserting 0 = 15.8° into Equation 5.23<br />

gives<br />

(5.26)<br />

(5.27)<br />

The actual specific mass flow rate using the bulk density pos = 0.475 g/cm 3 is therefore<br />

The conveying/ efficiency T]F is