BIO MUTO<br />

DAEYANG MEDICAL CO., LTD.<br />

Manual<br />

1


Contents<br />

Benefits <strong>of</strong> BIO MUTO ----------------------------------------------- 3<br />

Specifications ---------------------------------------------------------- 3<br />

Features <strong>of</strong> BIO MUTO ---------------------------------------------- 4<br />

Accessories ---------------------------------------------------------- 5<br />

How to use -------------------------------------------------------------- 6<br />

About Programs -------------------------------------------------------7<br />

Safety Precautions --------------------------------------------------- 8<br />

Reference --------------------------------------------------------------- 9<br />

Guarantee --------------------------------------------------------------- 16<br />

2


BENEFITS OF BIO MUTO<br />

1. An easy-to-use membrane panel designed for quick set-up and simple<br />

operation<br />

2. This new combo unit performs muscle stimulation and therapeutic<br />

ultrasound.<br />

3. The BIO MUTO features a 1-and-3-Mhz, 5 cm applicator for therapeutic<br />

ultrasound, plus the three most popular low frequencies.<br />

Specification.<br />

1. Model Name : BIO MUTO<br />

2. Mains Voltage : AC220V-230V~ 50/60Hz<br />

3. Power Consumption : 40VA<br />

4. US Output Frequency : 1MHz, 3MHz<br />

5. Output Low Frequency :5,10,30,50,100Hz<br />

6. Max. Output Current : 6mA<br />

7. Timer : 3 - 20(Min)<br />

8. Safety Device : Zero Start<br />

9. Protective System : CLASS 1, BF TYPE<br />

10. Weight : 4kg<br />

11. Dimension : 460(W) 270(D) 150(H)<br />

3


Features <strong>of</strong> BIO MUTO<br />

1. Digital display for Treatment Time<br />

2. Selection button for Treatment Time<br />

3. Selection dial for Low Frequency<br />

4. LED output indicators for Ultrasonic Intensity<br />

5. LED output indicators for Low Frequency Intensity<br />

6. Display for Programs - 1MHz pulse ratio : 1:2 , continue<br />

7. Display for Programs - 3MHz pulse ratio : 1:2 , continue<br />

8. Selection button for Ultrasonic Programs<br />

9. Intensity Controller <strong>of</strong> Low Frequency<br />

10. Intensity Controller <strong>of</strong> Ultrasonic<br />

11. Output receptacle for Electrode<br />

12. Output receptacle for Transducer 1MHz<br />

13. Output receptacle for Transducer 3MHz<br />

14. On/Off Switch<br />

4


Accessories<br />

1. Transducer 1MHz : Large Size ----------- 1<br />

2. Transducer 3MHz : Small Size ----------- 1<br />

3. Wire Leads and Pad for Electrode ------ 1<br />

4. Gel ---------------------------------------------- 1<br />

5. Instruction Manual -------------------------- 1<br />

5


How to use<br />

The operation <strong>of</strong> BIOMUTO is extremely simply.<br />

Please go through the following steps one after the other.<br />

1. Switching the set on – on the front panel<br />

After the power switch on, the BIO MUTO is immediately ready for operation.<br />

2. Turn all intensity dial <strong>of</strong>f – If intensity dial is on and treatment is not running.<br />

3. To set the treatment time use the Time S/W to increase the time.<br />

4. Select program with button in Mode.<br />

5. Select Frequency with frequency dial.<br />

6. Attach suitable electrode and Keep the face <strong>of</strong> transducer in contact with<br />

the treatment area.<br />

7. Turn on the stimulator output control and slowly increase the intensity until<br />

the patient just feels the normal.<br />

8. Turn on the ultrasound output. The patient may feel a slight increase to the<br />

sensation. Set the intensity to the required level.<br />

9. By using the intensity dial from zero, the unit is started immediately.<br />

10. When the treatment time reaches zero, then unit will give alarm.<br />

At the end <strong>of</strong> treatment, remove the transducer from the treatment area.<br />

11. Turn <strong>of</strong>f the all intensity dial.<br />

If you should “lose your way” can not get out by error, simply switch the unit<br />

<strong>of</strong>f and begin again.<br />

6


About Programs<br />

1MHz Output : Continuous<br />

3MHz Output : Continuius<br />

Pulsed Output<br />

Pulse Ratios : 1:2<br />

7


Safety Precautions<br />

Must not be applied to brain, backbone, eye, heart, testicles, ovary, pregnant<br />

womb, good or bad tumor and tuberculosis.<br />

Not suitable for the application to the following : bleeding, circulation troubles<br />

( thrombus arterial sclerosis, etc.), acute inflammation <strong>of</strong> joint and bone,<br />

suppuration <strong>of</strong> s<strong>of</strong>t tissues, etc.<br />

Patients with Heart pacemakers bad/or other electronic implants<br />

Electro stimulation therapies or diagnoses should never be employed on<br />

patients with electronic implants, such as heart pacemakers, without obtaining<br />

prior approval <strong>of</strong> a specialist.<br />

Use only certified-safe accessory items.<br />

Use only those accessory items listed in the equipment’s instruction manual.<br />

Any other accessory items employed should be certified as safe for such use by<br />

a testing authority.<br />

8


Reference<br />

1. What is Ultrasonic Wave?<br />

The sound humans can hear is called audible sound.<br />

It’s range covers 300Hz to 3,400Hz. There is no definite boundary between audible sound and<br />

ultrasonic wave. Using these senses they can even detect the difference between metal and<br />

wood.<br />

Physiotherapists use ultra sonic wave every day. The waves vibrate the molecules, which<br />

causes heat and stimulates lymph and blood vessels. This physiological action then speeds up<br />

the healing process by draining toxins and increasing nutrients and oxygen to the tissues.<br />

2. Using Ultrasonic Wave in skin care<br />

Ultrasonic Wave Massager <strong>of</strong> BIO MUTO output 1 MHz (1 million Hz) per second.<br />

This causes a fine vibration <strong>of</strong> the cells within the tissues, penetrating the subcutaneous layers<br />

by as much as 5 cm .<br />

The physiological effect <strong>of</strong> this is, stimulation <strong>of</strong> blood and lymphatic vessels including<br />

circulation <strong>of</strong> both within 10 minutes. It also increases metabolism and mitotic activity as it<br />

energizes the cells.<br />

Different frequencies produce different results.<br />

The Ultrasonic Wave Massager <strong>of</strong> BIO MUTO has various settings; massage, whitening, wrinkle<br />

care and lifting for face. The whitening program works by restricting the production <strong>of</strong> melanin,<br />

the wrinkle care by increasing mitotic activity, the toning by stimulation and reduction <strong>of</strong> toxins<br />

and fatty deposits. The body program incorporates a stimulating massage with fat reduction as it<br />

penetrates the hypodermic fatty strata.<br />

The overall result is smooth, s<strong>of</strong>t, clear complexion and elimination <strong>of</strong> orange peel effect on<br />

Cellulite. As cell regeneration decreases after the age <strong>of</strong> 35, it is important to continue regular<br />

treatments to combat the ageing process and maintain a youthful look.<br />

3. Benefits <strong>of</strong> Ultrasonic Wave<br />

1. S<strong>of</strong>tens thickened spots and removes redness<br />

2. Reduces scarring from acne treatment, and reduces “black eye” ring/ puffy eye sack<br />

3. Removes or reduces abnormal skin discoloration and sub-dermal freckles<br />

4. Reduces and prevents facial wrinkles and extravagated blood<br />

5. Treats sclerosis, and prevents acne caused by congestion or inflammation <strong>of</strong> the lymphatic<br />

vessels.<br />

9


4. What is low frequency?<br />

Low-frequency is what stimulate the skin by constant current<br />

when the low electric current which has a regular rhythm infiltrated on the skin, it<br />

makes muscle relax and refresh body. The effect <strong>of</strong> massage depends on electric<br />

current power and operating time. Generally the low frequency effect <strong>of</strong> below 10Hz is<br />

almost same as handy tapping to stimulate kinetic neuron. On the contrary, if the<br />

frequency is more higher, it results <strong>of</strong> neuralgia sedation.<br />

5. Effects <strong>of</strong> Low-frequency<br />

1. Blood Circulation<br />

2. Cellulite Dissolution<br />

3. Muscular Relaxation<br />

4. Muscular Relaxation<br />

5. Anti-Stress<br />

10


6. What is BIO MUTO?<br />

BIO MUTO is a treatment that combines iontophoresis and sonophoresis using specially ionized skin<br />

peeling medicine and vitamins.<br />

Although vitamins were proved to be highly effective in reducing damaged skin, it was impossible for them<br />

to deeply penetrate the skin.<br />

Because our skin is protected by an outer layer, merely applying any products to the skin does not<br />

lead to the expected results, no matter how good the product is.<br />

‘Vital iont’ treatment is widely used, which uses an iontophoresis appliance that penetrates vitamin C into<br />

the skin cell and tissue.<br />

BIO MUTO is a treatment, which has further enhanced the effectiveness <strong>of</strong> the vital iont treatment.<br />

BIO MUTO makes a dramatic change to the skin.<br />

It adopts both existing iontophoresis and sonophoresis, which uses the optimum frequency for the<br />

penetration into the skin. It has increased the penetration <strong>of</strong> nutrients into the skin by 4000%.<br />

It uses what is known to be most effective in curing photoaging, such as, vitamins A, C and E, beta<br />

carotene and AHA. By applying these nutrients at an optimum rate BIO MUTO helps skin to be healthy.<br />

It controls pigmentation on the skin, keeping skin free from dark spots and leaving skin smooth.<br />

The BIO MUTO treatment is remarkably effective in eliminating wrinkles according to Dr Fernandez<br />

who developed the treatment. He commented, “With this technology in the future people will not<br />

need to have an operation to get rid <strong>of</strong> wrinkles.”<br />

The BIO MUTO treatment has already been broadly used by dermatologists and plastic surgeons in<br />

the US, Japan, Europe and Australia.<br />

In Korea, it has been recently adopted gradually demonstrating the successful treatment for various<br />

skin troubles.<br />

11


7. What is Laser?<br />

Prior to the treatment the assessment <strong>of</strong> the skin condition or problems<br />

(for example, the photosensitivity, hyper pigmentation, hypertrophic cicatrix, keloid and any inflammation)<br />

as well as the overall health condition is required<br />

The light from laser for the treatments <strong>of</strong> diseases related to the pigment and the blood vessel and<br />

<strong>of</strong> the hair restoration is harmful to the eye.<br />

During the treatment both the patient and the laser operator must wear protective spectacles.<br />

As the retina does not feel the pain, when exposed to the light from laser, the patient may firstly<br />

feel the vision impeded.<br />

Different lasers produce different wavelengths.<br />

Each laser needs protective spectacles that blocks the wavelength <strong>of</strong> light the laser emits.<br />

Prior to treatment make-up or sun block cream need to be completely removed, as they may affect the<br />

penetration <strong>of</strong> the laser.<br />

After the treatment, the patient progresses at various rates depending on the type <strong>of</strong> laser used for the<br />

treatment.<br />

In every case the patient must avoid exposing the laser treated area to the sun and apply sun-block<br />

cream to the area.<br />

Particularly, hyper pigmentation may occur to Koreans’ skin. Before and after the treatment, if required,<br />

it is recommended that Koreans apply ointments to the laser treated area, which help to whiten and<br />

restore the skin.<br />

* Blood vessel related disease<br />

1. Blood vessel related disease changes the color <strong>of</strong> the skin to blue immediately after the treatment.<br />

Pigment related disease colors the skin to grey or the color <strong>of</strong> a bruise (purple or brown)<br />

immediately after the treatment. It is clear for several hours after the treatment.<br />

Gradually the colors fade away and disappear one or two weeks later.<br />

2. Patents can put on make-up as scabs are not formed on the face.<br />

The patient may use the make-up base with the green color tone to cover the bluish color on the<br />

face caused by the treatment.<br />

* Pigment related disease<br />

1. Pigment related disease (such as spots, freckles and other specks)<br />

disappears one week after treatment when the scab falls <strong>of</strong>f.<br />

Flash wash and light make-up are allowed three days after the treatment when the scab is settled in.<br />

2. Avoid the sun. When outside, apply the sun-block product with a sun protection factor (SPF) <strong>of</strong> more<br />

than 15.<br />

3. Apply an anti-inflammatory ointment once or twice a day.<br />

4. Do not rub the treated area with a towel or a scrubber as the area is extremely sensitive.<br />

5. Do not take aspirins or other medicine that contain aspirin during the initial healing period,<br />

that is for one to two weeks after the treatment.<br />

12


6. Avoid playing strenuous sports such as swimming until the skin is completely healed.<br />

* Skin care after laser face peeling<br />

1. Two to four weeks prior to the laser peeling, apply a pre-treatment ointment. This pre-treatment<br />

ointment removes pigments and facilitates the skin restoration, properly preparing the skin for<br />

the laser peeling and controlling pigmentation after the treatment.<br />

2. When the swelling is severe, low the head to reduce it for two or three days.<br />

(I am not sure what this means)<br />

3. While the laser treated area is healing, take sufficient water and deep sleep.<br />

Make sure that the room is not dry.<br />

4. Make sure not to skip the medicine prescribed by the doctor.<br />

5. Visit the clinic on the scheduled day to check the skin condition<br />

and have the skin restoration treatment.<br />

6. Use only the face cleanser and the moisturizer that the doctor has prescribed after the laser peeling.<br />

7. To protect the skin from the sun put on a hat and an ultraviolet protection cream.<br />

13


Maintenance<br />

1. Safety Tips<br />

1) Unplug the electrical cord from<br />

the wall outlet when not in use<br />

2) Do not disassemble, modify,<br />

or attempt to fix the product.<br />

When repair is required, please<br />

call for service.<br />

3) If you hear or experience<br />

abnormal sounds or functions<br />

turn <strong>of</strong>f the power immediately<br />

and call for service.<br />

4) Do not bend or mistreat the<br />

power cord. This may result in<br />

electrical shock.<br />

5) Unplug product from electrical<br />

outlet in the event <strong>of</strong> an electrical<br />

storm to avoid damage, electric<br />

shock, or fire.<br />

6) Do not handle or pull the<br />

power cord with wet hands. This<br />

may result in electrical shock.<br />

7)Do not plug product into<br />

electrical outlets shared with<br />

other electric appliances. This<br />

may result in fire.<br />

8) Do not use damaged power<br />

cords, or outlet. This may result<br />

in fire or electrical shock.<br />

10) When toe product is exposed to water or<br />

moister, unplug the outlets and do not use.<br />

11) Do not use the product in the bathroom or<br />

kitchen.<br />

14


2. Before Calling for Service<br />

I don’t see any sign <strong>of</strong> light on the front panel.<br />

Did you check the power cord?<br />

Did you check the power switch?<br />

Did you check the fuse?<br />

The Low frequency doesn’t work<br />

The ultrasound doesn’t work<br />

Check Solution<br />

Plug into wall outlet<br />

Power on the switch<br />

Replace the fuse.<br />

If possible persist, unplug and call for service.<br />

Check Solution<br />

Did you check the connections?<br />

Plug in the output socket.<br />

Did you turn on the volume?<br />

Turn on the volume.<br />

Did you set all intensity volume to Zero? Set all intensity to Zero<br />

If possible persist, unplug and call for service.<br />

Check Solution<br />

Did you check the connections?<br />

Plug in the output socket.<br />

Did you turn on the volume?<br />

Turn on the volume.<br />

Did you set all intensity volume to Zero? Set all intensity to Zero<br />

If possible persist, unplug and call for service.<br />

15


DAEYANG MEDICAL BIO MUTO<br />

LIMITED PRODUCT WARRANTY STATEMENT<br />

LIMITED WARRANTY<br />

The Daeyang Medical co.,ltd. Provides the assurance <strong>of</strong> the product accourding to applicable consumer protection<br />

law(s).<br />

The Product you have purchased from an authorized Daeyang Retail Distributor is free from defects in materials or<br />

workmanship under normal use during the warranty period. This limited warranty is valid only in the United<br />

Kingdom<br />

If any problem should occur, please try to resolve the problem first by contacting the place from which you<br />

purchased the product. If you are unable to obtain appropriate service, please call the company directly.<br />

The parts <strong>of</strong> the specified product are available for a period <strong>of</strong> 3 years from the date <strong>of</strong> discontinuation <strong>of</strong> the<br />

aforementioned product. Major parts <strong>of</strong> the specified product, such as PCB, or connector are available for a period<br />

<strong>of</strong> up to but not more than 5 years from the date <strong>of</strong> discontinuation.<br />

Product Name BIO MUTO Customer Name<br />

Model No. Address Line 1<br />

Serial No. Address Line 2<br />

Warranty Period 1 years from date <strong>of</strong> purchase City, State<br />

Date <strong>of</strong> Purchase Zip Code<br />

Place <strong>of</strong> Purchase Phone No.<br />

Be sure to have the manager at the place <strong>of</strong> purchase fill out the chart above to confirm future warranty service.<br />

SERVICE WITHOUT ADDITIONAL CHARGE<br />

You are entitled to service without charge only. In terms <strong>of</strong> parts and labor, if product is less than 1 years old from the<br />

date <strong>of</strong> purchase, and if the product has not been damaged or broken despite its use under normal circumstances. The<br />

duration <strong>of</strong> warranty service without charge maybe reduced to 1 year, at Daeyang’ option, if the product has either been<br />

used on a more than frequent basis and/or the product has been used for purposes other than mentioned in the manual<br />

in any ways, shapes or forms.<br />

SERVICE WITH ADDITIONAL CHARGE<br />

In order to expedite service and continue customer satisfaction, please check to see if any <strong>of</strong> the following problems ma<br />

be solved prior to requesting service. Otherwise, there may be additional charges for service <strong>of</strong> the following. The<br />

product itself may not be out <strong>of</strong> order, so please check to see it;<br />

The product is not plugged into a 240V wall outlet.<br />

The purchaser set up or installed the product improperly.<br />

The product’s connections have been improperly connected.<br />

The product was used incorrectly.<br />

16


LIMITATIONS<br />

The purchaser may be responsible for damager <strong>of</strong> the product, at Daeyang Medical Co.,Ltd.’s evaluation, if;<br />

An unauthorized or non-affiliated person attempted to fix or modify the product.<br />

The purchaser attempted to disassemble or remodel the parts <strong>of</strong> the product.<br />

Damage occurred from the misuse, abuse or neglect <strong>of</strong> the product or parts <strong>of</strong> the product.<br />

Damage resulted from any natural calamities or an act <strong>of</strong> God.<br />

Unattached parts, such as the panels, pad, belt, have been worn out by normal and routine wear.<br />

TERMS OF THE WARRANTY<br />

This warranty commences from the date <strong>of</strong> purchase stated on the sales receipt and/or sales contract. This warranty<br />

extends only to the original purchaser, and is not transferable to anyone who subsequently purchased the product from<br />

the original purchaser. Except as expressly set forth in the warranty, Daeyang Medical Co.,Ltd. Lakes no other<br />

warranties, neither the personnel <strong>of</strong> the seller nor any other person is authorized to make any additional warranty than<br />

that described above, or to extend the duration <strong>of</strong> any warranty beyond the time period as stated above.<br />

17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!