<strong>Flow</strong> <strong>Analyser</strong><br />

<strong>PF</strong>-<strong>300</strong> / -<strong>301</strong> <strong>VAC</strong> / -<strong>302</strong> <strong>LOW</strong><br />

Measuring your<br />

pneumatic equipment<br />

for reliability and<br />

precision with a<br />

dependable calibration<br />

tool is critical in<br />

avoiding fatal errors.<br />

Precision and<br />

reliability are exactly<br />

what the <strong>Flow</strong><strong>Analyser</strong><br />

Product Line provides.<br />

The <strong>Flow</strong><strong>Analyser</strong> measures flow, pressure, temperature, humidity and O2<br />

concentrations bi-directionally. The one-of-a-kind Adult, Pediatric and High<br />

Frequency ventilation measuring modes make the <strong>Flow</strong><strong>Analyser</strong> the ideal calibration<br />

tool for all ventilators, anesthesia machines and spirometers. The <strong>Flow</strong><strong>Analyser</strong><br />

distinguishes itself from other calibration tools by combining a simple, intuitive<br />

multilingual user interface with the highest precision.<br />

With the push of a button, all measured values can be stored directly on the<br />

<strong>Flow</strong><strong>Analyser</strong> and later retrieved for documentation purposes. <strong>Flow</strong>Lab software<br />

complements the <strong>Flow</strong><strong>Analyser</strong> by offering a wide range of graphical analysis<br />

capabilities. Swiss devotion to detail at its best<br />

<strong>PF</strong>-<strong>300</strong><br />

The standard model<br />

for universal applications<br />

<strong>PF</strong>-<strong>301</strong> <strong>VAC</strong><br />

Includes an additional<br />

sensor for<br />

vacuum measurements<br />

up to +/-1 bar<br />

<strong>PF</strong>-<strong>302</strong> <strong>LOW</strong><br />

Includes an additional<br />

sensor measuring<br />

minimal pressures<br />

up to 5 mbar<br />

mtk <strong>Peter</strong> <strong>Kron</strong> <strong>GmbH</strong> Mess-Systeme für Medizintechnik Hard & Software<br />

Zossener Straße 41, D-10961 Berlin Tel.+49 (0)30 / 69 81 88-40 Fax. +49 (0)30 69 81 88-49<br />

Freeline 0800 040 50 30 www.mtk-biomed.de info@mtk-biomed.de


Specifications*<br />

Measurements <strong>PF</strong>-<strong>300</strong> <strong>PF</strong>-<strong>301</strong> <strong>PF</strong>-<strong>302</strong><br />

<strong>Flow</strong> Measuring direction bidirectional x x x<br />

Temperature compensated yes x x x<br />

Pressure compensated yes x x x<br />

Humidity compensated yes x x x<br />

O2 compensated yes x x x<br />

High ± <strong>300</strong> L/min x x x<br />

Low ± 20 L/min x x x<br />

Pressure High 0-10 bar x x x<br />

Average ± 150 mbar Diff Rel Rel<br />

Low 0-5 mbar x<br />

High in <strong>Flow</strong> Canal 0-150 mbar x x x<br />

Barometer 0-1150 mbar (abs) x x x<br />

Vacuum pressure ± 1000 mbar x<br />

Measuring Units <strong>Flow</strong> L/min, L/s, cfm, mL/min, mL x x x<br />

Additional Measuring Values<br />

Pressure<br />

bar, mbar, cmH2O, inH2O, Torr,<br />

inHg, hPa, kPa, mmHg, PSI<br />

x x x<br />

Oxygen Concentration 0-100% x x x<br />

Pressure compensated yes x x x<br />

Temperature High in <strong>Flow</strong> Canal 0-50°C x x x<br />

Dew point High in <strong>Flow</strong> Canal -10-50°C x x x<br />

Air humidity High in <strong>Flow</strong> Canal 0-100% x x x<br />

CO2 Concentration 0-10% with OR-703<br />

N2O Concentration 0-100% with OR-703<br />

HAL, ISO, ENF Concentration 0-12% with OR-703<br />

SEV Concentration 0-15% with OR-703<br />

DES Concentration 0-22% with OR-703<br />

Gas types Air, Air/O2, N2O/O2, Heliox (21% O2),<br />

He/O2, N2, CO2, customized gas types<br />

x x x<br />

Gas standardisation ATP, ATPD, ATPS, AP21, STP, STPH, BTPS, BTPD,<br />

0/1013, 20/981, 15/1013, 25/991, 20/1013<br />

x x x<br />

Respiratory Parameters<br />

Rate 1-1000 bpm/min x x x<br />

Time TI, TE 0.05-60 s x x x<br />

I:E ratio 1:<strong>300</strong> - <strong>300</strong>: x x x<br />

Ti/Ttotal 0-100% x x x<br />

Breath volumes Vti, Vte ±10L x x x<br />

Minute volumes Vi, Ve 0-<strong>300</strong> L/min x x x<br />

Pressure Ppeak, Pmean, PEEP, Pplateau 0-150 mbar x x x<br />

Peakflow Peakflow Insp./Exp. ±<strong>300</strong> L/min x x x<br />

Compliance Cstat 0-1000 mL x x x<br />

Trigger Adult, Pediatric, HFO Adjustable on flow or pressure<br />

curves with user-definded limits<br />

x x x<br />

General Information<br />

Electrical & Physical Data AC input 90-260 <strong>VAC</strong>, 50/60 Hz x x x<br />

Battery (lead recharcheable battery 3 hrs (with OR-703 2 hrs x x x<br />

Power consumption 23 VA x x x<br />

Weight 3.7 kg x x x<br />

Dimensions (w x d x h) 22 x 25 x 12 cm x x x<br />

Data Storage all parameters (measured as well as<br />

respiratory values)<br />

x x x<br />

Display Graphic display Intuitive user interface with numerical<br />

measuring values, statistics, volume trigger<br />

configuration, gas type selection<br />

and calibration menus.<br />

x x x<br />

Communication Interfaces USB for Windows Software <strong>Flow</strong>LabTM,<br />

RS-232 for individual communication,<br />

TTL for external trigger.<br />

x x x<br />

Calibration annually x x x<br />

Conditions Ambient Pressure 10-40°C (50-104°F) x x x<br />

Humidity 10-95% R.H. x x x<br />

Approvals CE, CSA x x x<br />

*Specifications subject to change without norice<br />

mtk <strong>Peter</strong> <strong>Kron</strong> <strong>GmbH</strong> Mess-Systeme für Medizintechnik Hard & Software<br />

Zossener Straße 41, D-10961 Berlin Tel.+49 (0)30 / 69 81 88-40 Fax. +49 (0)30 69 81 88-49<br />

Freeline 0800 040 50 30 www.mtk-biomed.de info@mtk-biomed.de