Flow Analyser PF-300 / -301 VAC / -302 LOW - MTK Peter Kron GmbH
Flow Analyser PF-300 / -301 VAC / -302 LOW - MTK Peter Kron GmbH
Flow Analyser PF-300 / -301 VAC / -302 LOW - MTK Peter Kron GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Flow</strong> <strong>Analyser</strong><br />
<strong>PF</strong>-<strong>300</strong> / -<strong>301</strong> <strong>VAC</strong> / -<strong>302</strong> <strong>LOW</strong><br />
Measuring your<br />
pneumatic equipment<br />
for reliability and<br />
precision with a<br />
dependable calibration<br />
tool is critical in<br />
avoiding fatal errors.<br />
Precision and<br />
reliability are exactly<br />
what the <strong>Flow</strong><strong>Analyser</strong><br />
Product Line provides.<br />
The <strong>Flow</strong><strong>Analyser</strong> measures flow, pressure, temperature, humidity and O2<br />
concentrations bi-directionally. The one-of-a-kind Adult, Pediatric and High<br />
Frequency ventilation measuring modes make the <strong>Flow</strong><strong>Analyser</strong> the ideal calibration<br />
tool for all ventilators, anesthesia machines and spirometers. The <strong>Flow</strong><strong>Analyser</strong><br />
distinguishes itself from other calibration tools by combining a simple, intuitive<br />
multilingual user interface with the highest precision.<br />
With the push of a button, all measured values can be stored directly on the<br />
<strong>Flow</strong><strong>Analyser</strong> and later retrieved for documentation purposes. <strong>Flow</strong>Lab software<br />
complements the <strong>Flow</strong><strong>Analyser</strong> by offering a wide range of graphical analysis<br />
capabilities. Swiss devotion to detail at its best<br />
<strong>PF</strong>-<strong>300</strong><br />
The standard model<br />
for universal applications<br />
<strong>PF</strong>-<strong>301</strong> <strong>VAC</strong><br />
Includes an additional<br />
sensor for<br />
vacuum measurements<br />
up to +/-1 bar<br />
<strong>PF</strong>-<strong>302</strong> <strong>LOW</strong><br />
Includes an additional<br />
sensor measuring<br />
minimal pressures<br />
up to 5 mbar<br />
mtk <strong>Peter</strong> <strong>Kron</strong> <strong>GmbH</strong> Mess-Systeme für Medizintechnik Hard & Software<br />
Zossener Straße 41, D-10961 Berlin Tel.+49 (0)30 / 69 81 88-40 Fax. +49 (0)30 69 81 88-49<br />
Freeline 0800 040 50 30 www.mtk-biomed.de info@mtk-biomed.de
Specifications*<br />
Measurements <strong>PF</strong>-<strong>300</strong> <strong>PF</strong>-<strong>301</strong> <strong>PF</strong>-<strong>302</strong><br />
<strong>Flow</strong> Measuring direction bidirectional x x x<br />
Temperature compensated yes x x x<br />
Pressure compensated yes x x x<br />
Humidity compensated yes x x x<br />
O2 compensated yes x x x<br />
High ± <strong>300</strong> L/min x x x<br />
Low ± 20 L/min x x x<br />
Pressure High 0-10 bar x x x<br />
Average ± 150 mbar Diff Rel Rel<br />
Low 0-5 mbar x<br />
High in <strong>Flow</strong> Canal 0-150 mbar x x x<br />
Barometer 0-1150 mbar (abs) x x x<br />
Vacuum pressure ± 1000 mbar x<br />
Measuring Units <strong>Flow</strong> L/min, L/s, cfm, mL/min, mL x x x<br />
Additional Measuring Values<br />
Pressure<br />
bar, mbar, cmH2O, inH2O, Torr,<br />
inHg, hPa, kPa, mmHg, PSI<br />
x x x<br />
Oxygen Concentration 0-100% x x x<br />
Pressure compensated yes x x x<br />
Temperature High in <strong>Flow</strong> Canal 0-50°C x x x<br />
Dew point High in <strong>Flow</strong> Canal -10-50°C x x x<br />
Air humidity High in <strong>Flow</strong> Canal 0-100% x x x<br />
CO2 Concentration 0-10% with OR-703<br />
N2O Concentration 0-100% with OR-703<br />
HAL, ISO, ENF Concentration 0-12% with OR-703<br />
SEV Concentration 0-15% with OR-703<br />
DES Concentration 0-22% with OR-703<br />
Gas types Air, Air/O2, N2O/O2, Heliox (21% O2),<br />
He/O2, N2, CO2, customized gas types<br />
x x x<br />
Gas standardisation ATP, ATPD, ATPS, AP21, STP, STPH, BTPS, BTPD,<br />
0/1013, 20/981, 15/1013, 25/991, 20/1013<br />
x x x<br />
Respiratory Parameters<br />
Rate 1-1000 bpm/min x x x<br />
Time TI, TE 0.05-60 s x x x<br />
I:E ratio 1:<strong>300</strong> - <strong>300</strong>: x x x<br />
Ti/Ttotal 0-100% x x x<br />
Breath volumes Vti, Vte ±10L x x x<br />
Minute volumes Vi, Ve 0-<strong>300</strong> L/min x x x<br />
Pressure Ppeak, Pmean, PEEP, Pplateau 0-150 mbar x x x<br />
Peakflow Peakflow Insp./Exp. ±<strong>300</strong> L/min x x x<br />
Compliance Cstat 0-1000 mL x x x<br />
Trigger Adult, Pediatric, HFO Adjustable on flow or pressure<br />
curves with user-definded limits<br />
x x x<br />
General Information<br />
Electrical & Physical Data AC input 90-260 <strong>VAC</strong>, 50/60 Hz x x x<br />
Battery (lead recharcheable battery 3 hrs (with OR-703 2 hrs x x x<br />
Power consumption 23 VA x x x<br />
Weight 3.7 kg x x x<br />
Dimensions (w x d x h) 22 x 25 x 12 cm x x x<br />
Data Storage all parameters (measured as well as<br />
respiratory values)<br />
x x x<br />
Display Graphic display Intuitive user interface with numerical<br />
measuring values, statistics, volume trigger<br />
configuration, gas type selection<br />
and calibration menus.<br />
x x x<br />
Communication Interfaces USB for Windows Software <strong>Flow</strong>LabTM,<br />
RS-232 for individual communication,<br />
TTL for external trigger.<br />
x x x<br />
Calibration annually x x x<br />
Conditions Ambient Pressure 10-40°C (50-104°F) x x x<br />
Humidity 10-95% R.H. x x x<br />
Approvals CE, CSA x x x<br />
*Specifications subject to change without norice<br />
mtk <strong>Peter</strong> <strong>Kron</strong> <strong>GmbH</strong> Mess-Systeme für Medizintechnik Hard & Software<br />
Zossener Straße 41, D-10961 Berlin Tel.+49 (0)30 / 69 81 88-40 Fax. +49 (0)30 69 81 88-49<br />
Freeline 0800 040 50 30 www.mtk-biomed.de info@mtk-biomed.de