Bul. Inst. Polit. Iaşi, t. LVIII (LXII), f. 4, 2012 67<br />

The input data required by heat exchanger model are: the pressure – p1<br />

[N/m 2 ], the velocity – c1 [m/s] and the temperature – t1 [°C] of the fluid in the<br />

inlet section of the channel. The parameters have the following values:<br />

p1 = 101378 N/m 2 , c1 = 1.025 m/s, t1 = 18 °C.<br />

Fig. 2 –The mesh for the air flow channel.<br />

The air pressure drop Δp was considered constant and was measured on<br />

the experimental stand. In order to obtain the temperature on the inner surface<br />

of the air flow channel was necessary to accomplish the temperatures<br />

distribution in the separating wall.<br />

Fig. 3 –Distribution of temperature in the separating wall.<br />

The forced convective heat transfer from flue gas to air takes place in<br />

laminar conditions, over a plane plate. Proper calculation methods for this case<br />

are presented in (Popescu, 2003), (Badea & Necula, 2000), (Leca et al., 1998).