GENERAL<br />

4<br />

-DF<br />

Indoor Unit<br />

General Description<br />

UNIT IDENTIFICATION<br />

Precision <strong>Air</strong> <strong>Conditioning</strong><br />

<strong>Technical</strong> <strong>Manual</strong> : 6259014 v1.3.0 02_2013<br />

Precision <strong>Air</strong> <strong>Conditioning</strong><br />

EASICOOL PRECISION AIR CONDITIONING RANGE<br />

DF <strong>Downflow</strong> Configuration<br />

6-60 Model Size (Expressed as Nominal Cooling in kW)<br />

X <strong>Air</strong> Cooled Remote Condenser<br />

WX Water Cooled<br />

CW Chilled Water<br />

2 Tandem Compressor Set<br />

EZ Series - EasiCool<br />

Example DF22X2-EZ<br />

INTRODUCTION Designed to provide environmental Precision air conditioning for applications such as<br />

Telecommunication Facilities, Computer Rooms, Clean Rooms and laboratories, the<br />

EasiCool range is available 17 models as direct expansion air cooled, 17 models as<br />

Water Cooled or 17 models as chilled water all single circuit. Full function units provide<br />

full control of temperature, humidity and filtration.<br />

CE DIRECTIVE<br />

The modular design of the EasiCool allows for flexible installation by grouping same or<br />

differing models and capacities to be installed side by side, thus providing multi<br />

circuit functionality.<br />

A full range of air cooled condensers is available with the direct expansion indoor units to<br />

provide a matched system with optional performance upgrade, refer to Outdoor Units - <strong>Air</strong><br />

Cooled Condensers.<br />

Also available is a full range of <strong><strong>Air</strong>edale</strong> water chillers to complement the chilled water<br />

indoor units.<br />

The unit is designed for the use of R407C, please refer to Optional Extras - General for<br />

alternative refrigerants.<br />

This manual covers the full range of <strong>Downflow</strong> configured models. For Upflow<br />

configured models, please refer to the Upflow <strong>Technical</strong> <strong>Manual</strong>.<br />

<strong><strong>Air</strong>edale</strong> certify that the equipment detailed in this manual conforms with the following<br />

EC Directives:<br />

Electromagnetic Compatibility Directive (EMC) 2004/108/EC<br />

Low Voltage Directive (LVD) 2006/95/EC<br />

Machinery Directive (MD) 89/392/EEC in the version<br />

2006/42/EC<br />

Pressure Equipment Directive (PED) 97/23/EC<br />

To comply with these directives appropriate national & harmonised standards have been<br />

applied. These are listed on the Declaration of Conformity, supplied with each product.