Bul. Inst. Polit. Iaşi, t. LVI (LX), f. 2, 2010 257<br />

Since the first contact between tool and bone, the recorded temperature starts to<br />

increase, and in a following study of data, a few points can be made.<br />

Fig. 6 – The fall of temperature.<br />

The starting temperature in the drilling point of the bone is 14.415 ºC. The<br />

temporal sequence of the temperature in the drilling point is shown in this chart:<br />

Table 1<br />

Temperature in the drilling point<br />

0 1 2 3 4 5 6 7 8<br />

14.42 16.96 18.40 21.81 27.61 26.49 32.11 46.18 51.25<br />

The drilling lasted 8.5 seconds. This is the chart for the increase of<br />

temperature according to the time.<br />

Fig. 7 – The increase of temperature.<br />

There is a tendency in the increase of temperature as the drill bit drills the<br />

bone. Some adjustments were made for the analysis of data, and the closest one<br />

was:<br />

(2) Tª = 16.5913 + 0.5518*Time^2.<br />

Against a linear regression, the quadratic function explained up to 95.87% of<br />

the total variability of data (5% more than the linear), making the adjustment