Bul. Inst. Polit. Iaşi, t. LVI (LX), f. 2, 2010 99<br />

Transducer was chosen and the whole system was built base on<br />

recommendations from the literature [3] – [5].<br />

Part of the measure is placed on two supports adjustable so that it can be<br />

defined by two points equal height verification. This determines a straight line,<br />

to which will determine the actual right - edge play. For measurement: using<br />

an inductive transducer type Hottinger Baldwin Messtechnik WA T-10mm,<br />

supplied with 20 V DC voltage from a source Hameg HM 8040-2. Output is<br />

taken from a data acquisition card National Instruments USB 6009.<br />

Measurement chain is completed with a PC. No other mode of signal<br />

conditioning is required. Virtual instrument was developed programming<br />

environment LabVIEW 8.2 Student Edition.<br />

The block diagram of the application is presented in Fig. 2 [6] and involves<br />

the DAQ Assistant Express VI, the Waveform Chart for displaying the<br />

acquired signal and also the Build Table and the Write to Measurement File<br />

blocks for writing the acquired signal values in a table and in a file for further<br />

analysis.<br />

Fig. 2 – The block diagram of the application [6].<br />

The DAQ Assistant may be founded in the Express Functions palette of<br />

the block diagram and it is needed to create and configure a task that reads a<br />

voltage level in a specified range from a DAQ device. After the DAQ Assistant<br />

is placed on the block diagram, a dialog box window is launched in order to<br />

configure the data acquisition system. The dialog box displays a list of channels<br />

of the installed DAQ device and from this list the physical channel to which the<br />

instrument connects the signal must be selected. The others configurations are<br />

related to terminal configuration (differential or single ended), acquisition mode<br />

(continuous or not), signal input range and rate of acquisition. The Write to<br />

Measurement File Express VI is used for storing the information about the data