04.03.2013 Views

2011 - Europe Direct Iasi

2011 - Europe Direct Iasi

2011 - Europe Direct Iasi

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

R.18.<br />

Title<br />

Authors<br />

Institution<br />

Description<br />

R.19.<br />

Title<br />

EUROINVENT <strong>2011</strong><br />

supported plug, over floating plug or over mandrel) or<br />

without inside guard.<br />

Depending on the ratio g / D (g-thickness of the wall,<br />

D-diameter of the processed tube), the tubes may have thin<br />

walls (g / D ≤ 0,21) or thick walls (g / D > 0,21). At the<br />

present moment, for the case of without inside guard<br />

drawing processes, of the thin walls tubes, made from cold<br />

hard malleable metallic materials and work hardenable,<br />

too, SONODRAW system will apply.<br />

The case of without inside guard drawing processes of the<br />

tubes, in SONODRAW system, means a processing with<br />

ultrasonic vibrations which are sent to the die, along the<br />

drawing direction; so, during the plastic deformation, it<br />

will obtain the “ultrasounds surface effect” or the<br />

“reduction of the metal-tool contact friction”. The wanted<br />

effect of the ultrasonic energy will be obtained when the<br />

ultrasounds will have high values of energy-ultrasounds<br />

longitudinal waves, as standing waves, with the die placed<br />

in a top position of the wave oscillation. The ultrasonic or<br />

ultrasounds waves are a variety of the elastic waves which<br />

have the frequency values between 16000 Hz and 10 10 Hz.<br />

Modifying starch based hydrogel hydrophilicity via "click"<br />

chemistry"<br />

A. Uliniuc 1,2 , M. Popa 1 , T. Hamaide 2<br />

1<br />

”Gheorghe Asachi” Technical University Iași,<br />

Faculty of Chemical Engineering and Environmental<br />

Protection, 2 Université de Lyon, Ingénierie des matériaux<br />

polymères, CNRS UMR 5223, Villeurbanne, France<br />

Biodegradable and biocompatible hydrogels are widely used for<br />

biomedical applications, as biomaterials for drug delivery<br />

applications. In the present study, in order to improve the<br />

macroscopic properties of our starch based hydrogels, we grafted<br />

PCL chains using “click” chemistry. The intermediate and final<br />

samples were characterized by FTIR, HR-MASS, TGA and<br />

swelling degree measurements.<br />

Correlation between morphology, magnetic and<br />

magnetotransport properties of electrodeposited [Fe/Pt]n<br />

multilayers<br />

Innovative Researches<br />

146

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!