APPLICATION APPLICATION RATES RATES<br />
The following formula should be used to calculate application rates.<br />
Application Rate (inches per hour) =<br />
Example:<br />
Emitter Flow Rate = 1 gph<br />
Spacing Between Emission Device = 18"<br />
Spacing Between Poly Laterals = 16"<br />
Question:<br />
What is the application rate?<br />
Solution:<br />
231 x 1<br />
Application Rate = 16 x 18 = .80"/hr<br />
1/2 gph<br />
Emitter<br />
Spacing Between Poly Laterals<br />
Spacing 12" 13" 14" 15" 16" 17" 18" 19" 20" 22" 24"<br />
12" .80 .74 .69 .64 .60 .57 .53 .51 .48 .44 .40<br />
18" .53 .49 .46 .43 .40 .38 .36 .34 .32 .29 .27<br />
24" .40 .37 .34 .32 .30 .28 .26 .25 .24 .22 .20<br />
2 gph<br />
Emitter<br />
Spacing Between Poly Laterals<br />
Spacing 12" 13" 14" 15" 16" 17" 18" 19" 20" 22" 24"<br />
12" 3.20 2.96 2.75 2.56 2.40 2.28 2.12 2.04 1.92 1.76 1.60<br />
18" 2.14 1.98 1.84 1.72 1.60 1.50 1.42 1.36 1.28 1.16 1.06<br />
24" 1.60 1.48 1.38 1.28 1.20 1.14 1.06 1.02 .96 .88 .80<br />
57<br />
231 x Emitter Flow Rates (gph)<br />
Spacing Between Poly Laterals (inches) x Spacing Between Emission Device (inches)<br />
A B<br />
APPLICATION RATES (inches/hour)<br />
Based on Nominal Flow Rates<br />
1 gph<br />
Emitter<br />
Spacing Between Poly Laterals<br />
Spacing 12" 13" 14" 15" 16" 17" 18" 19" 20" 22" 24"<br />
12" 1.60 1.48 1.38 1.28 1.20 1.14 1.06 1.02 .96 .88 .80<br />
18" 1.07 .99 .92 .86 .80 .75 .71 .68 .64 .58 .53<br />
24" .80 .74 .69 .64 .60 .57 .53 .51 .48 .44 .40