Table 11: Type 1 Diabetes Mellitus–Adult<br />
Treatment duration<br />
Treatment in combination with following basal <strong>insulin</strong>:<br />
12 weeks<br />
LANTUS<br />
12 weeks 12 weeks<br />
®<br />
LANTUS<br />
(<strong>insulin</strong> glargine)<br />
®<br />
LANTUS<br />
(<strong>insulin</strong> glargine)<br />
®<br />
(<strong>insulin</strong> glargine)<br />
APIDRA APIDRA Regular Human<br />
Insulin<br />
Pre-meal Post-meal Pre-meal<br />
Number of subjects treated 286 296 278<br />
A1c (%)<br />
Endstudy mean 7.46 7.58 7.52<br />
Adjusted mean change from baseline* -0.26 -0.11 -0.13<br />
Basal <strong>insulin</strong> dose (U/day)<br />
Endstudy mean 29.49 28.77 28.46<br />
Adjusted mean change from baseline 0.99 0.24 0.65<br />
Short-acting <strong>insulin</strong> dose<br />
Endstudy mean (U/day) 28.44 28.06 29.23<br />
Adjusted mean change from baseline -0.88 -0.47 1.75<br />
Severe hypoglycemia**<br />
Number of subjects (%) 24/286 (8.4) 25/296 (8.4) 28/278 (10.1)<br />
Rate (events/month/patient) 0.05 0.05 0.13<br />
Mean number of short-acting <strong>insulin</strong> injections per day 3.15 3.13 3.03<br />
* Adjusted mean change from baseline treatment difference (98.33% Confidence Interval for treatment difference): APIDRA premeal<br />
vs. Regular Human Insulin - 0.13 (-0.26; 0.01); APIDRA post meal vs. Regular Human Insulin 0.02 (-0.11; 0.16); APIDRA post<br />
meal vs. pre meal 0.15 (0.02; 0.29).<br />
** Events requiring assistance from third party for the entire treatment phase.<br />
Continuous Subcutaneous Insulin Infusion (CSII) (Type 1 Diabetes):<br />
To evaluate the use of APIDRA for administration using an external pump, a 12-week<br />
randomized, open-label, active-control study (APIDRA versus <strong>insulin</strong> aspart) was conducted in<br />
Type 1 diabetes patients (n = 59). A low monthly rate of catheter occlusion in both treatment<br />
groups was observed (APIDRA: 0.08 occlusions/month; <strong>insulin</strong> aspart: 0.15 occlusions/ month).<br />
A similar incidence of infusion site reactions was seen with APIDRA (n = 3/29; 10.3%) and<br />
<strong>insulin</strong> aspart (n = 4/30; 13.3%).<br />
APIDRA has been studied in the following pumps and infusion sets: Disetronic ® H-Tron ® plus<br />
V100 and D-Tron TM , with Disetronic catheters (Rapid TM , Rapid C TM and D TM , and Tender TM );<br />
and with MiniMed ® Models 506, 507, 507c and 508 with MiniMed catheters (Sof-set Ultimate<br />
QR TM , and Quick-set TM ).<br />
Page 32 of 61