03.03.2013 Views

CANopen Programmer's Manual - Maccon.de

CANopen Programmer's Manual - Maccon.de

CANopen Programmer's Manual - Maccon.de

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>CANopen</strong> Programmer’s <strong>Manual</strong> 3: Device Control, Configuration, and Status<br />

MOTOR MODEL NUMBER INDEX 0X6403<br />

Type Access Units Range Map PDO Memory<br />

String RW - - NO F<br />

Description<br />

The motor's mo<strong>de</strong>l number.<br />

MOTOR MANUFACTURER INDEX 0X6404<br />

Type Access Units Range Map PDO Memory<br />

String RW - - NO F<br />

Description<br />

The motor's manufacturer name.<br />

MOTOR DATA INDEX 0X2383<br />

Type Access Units Range Map PDO Memory<br />

Record RW - - NO -<br />

Description<br />

This record holds a variety of motor parameters.<br />

Note that all motor parameters are stored to non-volatile memory on the amplifier. The<br />

programmed values are preserved across power cycles. Sub-in<strong>de</strong>x 0 contains the number of subelements<br />

of this record.<br />

MOTOR TYPE INDEX 0X2383, SUB-INDEX 1<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RW - See Description, below. NO F<br />

Description<br />

Defines the type of motor connected to the amplifier:<br />

Type Description<br />

0 Rotary motor.<br />

1 Linear motor.<br />

MOTOR POLE PAIRS INDEX 0X2383, SUB-INDEX 2<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RW - 0 - 32,767 NO F<br />

Description<br />

Number of motor pole pairs (electrical cycles) per rotation. For example, a 1.8 <strong>de</strong>g/step motor<br />

would require setting motor poll pairs to 50.<br />

This parameter is only used for rotary motors. For linear motors its value is ignored.<br />

Copley Controls 91