3: Device Control, Configuration, and Status <strong>CANopen</strong> Programmer’s <strong>Manual</strong><br />

RUNNING SUM OF AMP CURRENT LIMIT INDEX 0X2117<br />

Type Access Units Range Map PDO Memory<br />

Integer16 RO 0.01% - YES R*<br />

Description<br />

Running sum of the amp current limit.<br />

D/A CONVERTER CONFIGURATION. INDEX 0X21E0<br />

Type Access Units Range Map PDO Memory<br />

Integer32 RW - - NO RF<br />

Description<br />

This parameter sets the mo<strong>de</strong> for the D/A converter on drives so equipped. The bits are mapped<br />

as follows:<br />

Bit Description<br />

0-3 Define the mo<strong>de</strong> of the D/A converter<br />

16-17 I<strong>de</strong>ntify the axis associated with the D/A converter<br />

Mo<strong>de</strong> Description<br />

0 <strong>Manual</strong> configuration (set using parameter 0x135)<br />

1 Actual current of configured axis<br />

D/A CONVERTER OUTPUT VALUE INDEX 0X21E1<br />

Type Access Units Range Map PDO Memory<br />

Integer16 mV - R<br />

Description<br />

For drives that support an auxiliary D/A converter, this parameter sets the output value in mV units<br />

when the D/A is in manual mo<strong>de</strong>. In other mo<strong>de</strong>s, the current value being output on the D/A can<br />

be read here.<br />