<strong>CANopen</strong> Programmer’s <strong>Manual</strong> 3: Device Control, Configuration, and Status<br />

FPGA IMAGE VERSION INDEX 0X6510, SUB-INDEX 27<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 16 RO - - NO R<br />

FPGA firmware version number (available on certain amplifier mo<strong>de</strong>ls).<br />

SECONDARY FIRMWARE VERSION INDEX 0X6510, SUB-INDEX 28<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 32 RO - - NO R<br />

Firmware version of second processor for amplifiers equipped with two processors.<br />

FIRMWARE VERSION NUMBER (EXTENDED) INDEX 0X2422<br />

Type Access Units Range Map PDO Memory<br />

Integer 32 RO - - NO F<br />

Description<br />

Firmware Version Number (exten<strong>de</strong>d). The upper 16 bits give the same major/minor version<br />

number as Firmware Version Number (In<strong>de</strong>x 0x2384, Sub-In<strong>de</strong>x 24<br />

, p. 83). The lower 16 bits hold a release number (upper byte) and a reserved byte (lower).<br />

DEVICE TYPE INDEX 0X67FF<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 32 RO - - NO -<br />

Description<br />

Holds the same data as object 0x1000. Repeated as required by the <strong>CANopen</strong> specification.<br />

PWM MODE INDEX 0X2140<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 16 RW - See Description, below. NO RF<br />

Description<br />

PWM mo<strong>de</strong> and status. This bit-mapped register allows some <strong>de</strong>tails of the PWM output to be<br />

controlled and monitored. Fields are <strong>de</strong>scribed below:<br />

Bit Description<br />

0 Force bus clamping if set, disable bus clamping if clear. Note that if bit 1 is set, then this bit is ignored.<br />

1 Automatic bus clamping mo<strong>de</strong> if set. Setting this bit causes bus clamping mo<strong>de</strong> to be automatically selected<br />

based on the output voltage. Bit 0 is ignored if this bit is set.<br />

3 Factory reserved. If set, DBrk mo<strong>de</strong> is enabled.<br />

4 Use hex voltage limiting if set, circular limiting if clear. This setting is only used with brushless motors.<br />

6 Double PWM frequency if set.<br />

8 Status bit, set when bus clamping is active.<br />

RUNNING SUM OF USER CURRENT LIMIT INDEX 0X2116<br />

Type Access Units Range Map PDO Memory<br />

Integer16 RO 0.01% - YES R*<br />

Description<br />

Running sum of user current limit.<br />

Copley Controls 87