<strong>CANopen</strong> Programmer’s <strong>Manual</strong> 3: Device Control, Configuration, and Status<br />
QUICK STOP OPTION CODE INDEX 0X605A<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RW - See Description, below. NO R<br />
Description<br />
This object <strong>de</strong>fines the behavior of the amplifier when a quick stop command is issued. The<br />
following values are <strong>de</strong>fined.<br />
Value Description<br />
0 Disable the amplifier's outputs<br />
1 Slow down using the normal slow down ramp programmed in Profile Deceleration (in<strong>de</strong>x 0x6084, p. 204).<br />
When the move has been successfully aborted the amplifier's state will transition to the 'switch on disabled'<br />
state.<br />
2 Slow down using the quick stop ramp programmed in Quick Stop Deceleration (in<strong>de</strong>x 0x6085, p. 205) then<br />
transition to 'switch on disabled'.<br />
3 Stop the move abruptly and transition to 'switch on disabled'.<br />
5 Slow down using the slow down ramp. The amplifier state will remain in the 'quick stop' state after the move<br />
has been finished.<br />
6 Slow down using the quick stop ramp and stay in 'quick stop' state.<br />
7 Stop the move abruptly and stay in 'quick stop' state.<br />
All other values will produce unspecified results and should not be used.<br />
SHUTDOWN OPTION CODE INDEX 0X605B<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RW - See Description, below. NO R<br />
Description<br />
This object <strong>de</strong>fines the behavior of the amplifier when the amplifier's state is changed from<br />
“operation enabled” to “ready to switch on.” The following values are <strong>de</strong>fined:<br />
Value Description<br />
0 Disable the amplifier's outputs.<br />
1 Slow down using the slow down ramp (i.e. the normal move <strong>de</strong>celeration value).<br />
All other values will produce unspecified results and should not be used.<br />
DISABLE OPERATION OPTION CODE INDEX 0X605C<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RW - See Description, below. NO R<br />
Description<br />
This object <strong>de</strong>fines the behavior of the amplifier when the amplifier's state is changed from<br />
“operation enabled” to “switched on.” The following values are <strong>de</strong>fined.<br />
Value Description<br />
0 Disable the amplifier's outputs.<br />
1 Slow down using the slow down ramp (i.e. the normal move <strong>de</strong>celeration value).<br />
All other values will produce unspecified results and should not be used.<br />
Copley Controls 63