2: Network Management <strong>CANopen</strong> Programmer’s <strong>Manual</strong><br />

COB-ID SYNC MESSAGE INDEX 0X1005<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 32 RW - See SYNC ID Format, below. NO R<br />

Description<br />

This object <strong>de</strong>fines the CAN object ID (COB-ID) associated with the SYNC message. The SYNC<br />

message is a standard <strong>CANopen</strong> message type used to synchronize multiple <strong>de</strong>vices on a<br />

<strong>CANopen</strong> network.<br />

SYNC ID Format<br />

The SYNC message ID is formatted as follows:<br />

Bits Description<br />

0-10 Give the 11-bit i<strong>de</strong>ntifier for standard (CAN 2.0A) i<strong>de</strong>ntifiers, or the lower 11 bits for exten<strong>de</strong>d (CAN 2.0B)<br />

i<strong>de</strong>ntifiers.<br />

11-28 Give the upper 18 bits of exten<strong>de</strong>d i<strong>de</strong>ntifiers. For standard i<strong>de</strong>ntifiers these bits should be written as zeros.<br />

29 I<strong>de</strong>ntifier format. This bit is clear for standard (11-bit) i<strong>de</strong>ntifiers, and set for exten<strong>de</strong>d (29-bit) i<strong>de</strong>ntifiers.<br />

30 If set, the amplifier is configured as the SYNC message producer. This bit should be set in at most one<br />

amplifier on a network.<br />

31 Reserved<br />

COMMUNICATION CYCLE PERIOD INDEX 0X1006<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 32 RW microseconds - NO R<br />

Description<br />

This object <strong>de</strong>fines the interval between SYNC messages in units of microseconds.<br />

An amplifier configured as a SYNC message producer will not produce SYNC messages unless<br />

this object contains a non-zero value. A value of zero in this object disables SYNC message<br />

production.<br />

Amplifiers not configured to produce SYNC messages ignore the value of this object.<br />

GUARD TIME INDEX 0X100C<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 16 RW milliseconds - NO R<br />

Description<br />

This object gives the time between no<strong>de</strong>-guarding requests that are sent from the network master<br />

to this amplifier. The amplifier will respond to each request with a no<strong>de</strong>-guarding message<br />

indicating the internal state of the amplifier.<br />

If the amplifier has not received a no<strong>de</strong>-guarding request within the time period <strong>de</strong>fined by the<br />

product of the guard time and the Life Time Factor (in<strong>de</strong>x 0x100D, p. 47), the amplifier will treat<br />

this lack of communication as a fault condition.<br />

46 Copley Controls