<strong>CANopen</strong> Programmer’s <strong>Manual</strong> 1: Introduction<br />

RECEIVE PDO MAPPING PARAMETERS INDEX 0X1700<br />

Type Access Units Range Map PDO Memory<br />

Record RW - - NO -<br />

Description<br />

These objects allow the mapping of each of the receive PDO objects to be configured.<br />

NUMBER OF MAPPED OBJECTS INDEX 0X1700, SUB-INDEX 0<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 8 RW - 0-4 NO R<br />

Description<br />

This value gives the total number of objects mapped to this PDO. Once the PDO mapping has<br />

been established by configuring the objects in sub-in<strong>de</strong>xes 1 – 4, this value should be updated to<br />

indicate the actual number of objects mapped to the PDO.<br />

PDO MAPPING INDEX 0X1700, SUB-INDEX 1 – 4<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 32 RW - See Description, below NO R<br />

Description<br />

When a PDO message is received, the data passed with the PDO message (up to 8 bytes) is<br />

used to update the objects mapped to the PDO. The values in the PDO mapping objects i<strong>de</strong>ntify<br />

which object(s) the PDO data maps to. The first object is specified by the value in sub-in<strong>de</strong>x 1; the<br />

second object is i<strong>de</strong>ntified by sub-in<strong>de</strong>x 2, etc.<br />

Each of the PDO mapping values consist of a 32-bit value structured as follows:<br />

Bit Description<br />

0-7 Size (in bits) of the object being mapped. Must match the actual object size as <strong>de</strong>fined in the object<br />

dictionary.<br />

8-15 Sub-in<strong>de</strong>x of the object to be mapped.<br />

16-31 In<strong>de</strong>x of the object to be mapped.<br />

Because In<strong>de</strong>x 0x1700 is read only, the available mapped objects are fixed. They inclu<strong>de</strong> the<br />

following:<br />

Sub-in<strong>de</strong>x Value Description<br />

0 4 Number of mapped objects.<br />

1 0x60400010 Control word<br />

2 0x607A0020 Target position<br />

3 0x60B10020 Offset ad<strong>de</strong>d to the velocity command in CSP or CSV mo<strong>de</strong>.<br />

4 0x60B20010 Offset ad<strong>de</strong>d to the torque command in CSP, CSV or CST mo<strong>de</strong>s.<br />