4: Control Loop Configuration <strong>CANopen</strong> Programmer’s <strong>Manual</strong><br />
CURRENT LOOP OUTPUT, D AXIS INDEX 0X2218<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RO 0.1 V - YES -<br />
Description<br />
Part of the internal current loop calculation. Also known as Terminal Voltage Stepper.<br />
CURRENT LOOP OUTPUT, Q AXIS INDEX 0X2219<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RO 0.1 V - YES -<br />
Description<br />
Part of the internal current loop calculation. Also known as Terminal Voltage Servo.<br />
ACTUAL MOTOR CURRENT INDEX 0X221C<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RO 0.01 amps - YES -<br />
Description<br />
Actual motor current.<br />
COMMANDED CURRENT INDEX 0X221D<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RO 0.01 amps - YES -<br />
Description<br />
Instantaneous comman<strong>de</strong>d current as applied to the current limiter.<br />
LIMITED CURRENT INDEX 0X221E<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RO 0.01 amps - YES -<br />
Description<br />
Output of the current limiter (input to the current loop).<br />
PROGRAMMED CURRENT COMMAND INDEX 0X2340<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RW 0.01 amps - YES RF<br />
Description<br />
This object gives the programmed current value used when running in programmed current mo<strong>de</strong><br />
(mo<strong>de</strong> 1) or diagnostic micro-stepping mo<strong>de</strong> (mo<strong>de</strong> 42). (See Desired State object, p. 65, and<br />
Alternative Control Sources Overview, p. 225.)<br />
COMMANDED CURRENT RAMP RATE INDEX 0X2113<br />
Type Access Units Range Map PDO Memory<br />
Integer 32 RW mA/second - YES RF<br />
Description<br />
Setting this to zero disables slope limiting in Profile Torque mo<strong>de</strong>. It is also used when the<br />
amplifier is running in Programmed Current mo<strong>de</strong> (Desired State object [in<strong>de</strong>x 0x2300, p. 65] = 1).<br />
152 Copley Controls