4: Control Loop Configuration <strong>CANopen</strong> Programmer’s <strong>Manual</strong><br />

CURRENT LOOP OUTPUT, D AXIS INDEX 0X2218<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RO 0.1 V - YES -<br />

Description<br />

Part of the internal current loop calculation. Also known as Terminal Voltage Stepper.<br />

CURRENT LOOP OUTPUT, Q AXIS INDEX 0X2219<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RO 0.1 V - YES -<br />

Description<br />

Part of the internal current loop calculation. Also known as Terminal Voltage Servo.<br />

ACTUAL MOTOR CURRENT INDEX 0X221C<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RO 0.01 amps - YES -<br />

Description<br />

Actual motor current.<br />

COMMANDED CURRENT INDEX 0X221D<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RO 0.01 amps - YES -<br />

Description<br />

Instantaneous comman<strong>de</strong>d current as applied to the current limiter.<br />

LIMITED CURRENT INDEX 0X221E<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RO 0.01 amps - YES -<br />

Description<br />

Output of the current limiter (input to the current loop).<br />

PROGRAMMED CURRENT COMMAND INDEX 0X2340<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RW 0.01 amps - YES RF<br />

Description<br />

This object gives the programmed current value used when running in programmed current mo<strong>de</strong><br />

(mo<strong>de</strong> 1) or diagnostic micro-stepping mo<strong>de</strong> (mo<strong>de</strong> 42). (See Desired State object, p. 65, and<br />

Alternative Control Sources Overview, p. 225.)<br />

COMMANDED CURRENT RAMP RATE INDEX 0X2113<br />

Type Access Units Range Map PDO Memory<br />

Integer 32 RW mA/second - YES RF<br />

Description<br />

Setting this to zero disables slope limiting in Profile Torque mo<strong>de</strong>. It is also used when the<br />

amplifier is running in Programmed Current mo<strong>de</strong> (Desired State object [in<strong>de</strong>x 0x2300, p. 65] = 1).<br />