<strong>CANopen</strong> Programmer’s <strong>Manual</strong> 4: Control Loop Configuration<br />
USER PEAK CURRENT LIMIT INDEX 0X2110<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RW 0.01 amps 0 – 32,767 YES RF<br />
Description<br />
User peak current limit. Known as boost current on stepper amplifiers. This value cannot exceed<br />
the peak (or boost) current rating of the amplifier.<br />
USER CONTINUOUS CURRENT LIMIT INDEX 0X2111<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RW 0.01 amps 0 – 32,767 YES RF<br />
Description<br />
User Continuous Current Limit. Also known as Run Current on stepper amplifiers. This value<br />
should be less then the User Peak Current Limit. The amplifier uses this value as an input to an<br />
I 2 T current limiting algorithm to prevent over stressing the load.<br />
USER PEAK CURRENT LIMIT TIME INDEX 0X2112<br />
Type Access Units Range Map PDO Memory<br />
Unsigned 16 RW milliseconds 0 – 10,000 YES RF<br />
Description<br />
Specifies the maximum time at peak current. The amplifier uses this value as an input to an I 2 T<br />
current limiting algorithm to prevent over stressing the load.<br />
Also known as Time at Boost Current on stepper amplifiers.<br />
ACTUAL CURRENT, D AXIS INDEX 0X2214<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RW 0.01 amps - YES -<br />
Description<br />
Part of the internal current loop calculation.<br />
ACTUAL CURRENT, Q AXIS INDEX 0X2215<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RO 0.01 amps - YES -<br />
Description<br />
Part of the internal current loop calculation.<br />
CURRENT COMMAND, D AXIS INDEX 0X2216<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RO 0.01 amps - YES -<br />
Description<br />
Part of the internal current loop calculation.<br />
CURRENT COMMAND, Q AXIS INDEX 0X2217<br />
Type Access Units Range Map PDO Memory<br />
Integer 16 RO 0.01 amps - YES -<br />
Description<br />
Part of the internal current loop calculation.<br />