<strong>CANopen</strong> Programmer’s <strong>Manual</strong> 4: Control Loop Configuration<br />

VELOCITY LOOP MAXIMUM DECELERATION INDEX 0X2101<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 32 RW 1000 enc counts / sec 2<br />

0 – 100,000,000 YES RF<br />

Description<br />

This acceleration value limits the maximum rate of change of the comman<strong>de</strong>d velocity input to the<br />

velocity loop. This limit only applies when the absolute value of the velocity change is negative (i.e.<br />

the speed is <strong>de</strong>creasing in either direction).<br />

VELOCITY LOOP EMERGENCY STOP DECELERATION INDEX 0X2102<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 32 RW 1000 enc counts / sec 2<br />

0 – 100,000,000 YES RF<br />

Description<br />

The <strong>de</strong>celeration rate used during the time that the amplifier is trying to actively stop a motor<br />

before applying the brake output.<br />

Also known as the Velocity Loop Fast Stop Ramp.<br />

Note that this feature is not used when the position loop is driving the velocity loop. In that case,<br />

the trajectory generator's abort acceleration is used.<br />

VELOCITY LOOP – MAXIMUM VELOCITY INDEX 0X2103<br />

Type Access Units Range Map PDO Memory<br />

Integer 32 RW 0.1 counts/sec 0 – 500,000,000 YES RF<br />

Description<br />

This velocity value is a limit on the comman<strong>de</strong>d velocity used by the velocity loop.<br />

Also known as the Velocity Loop Velocity Limit.<br />

The velocity loop's comman<strong>de</strong>d velocity can be generated by several sources, including the output<br />

of the position loop. Velocity Loop-Maximum Velocity allows that velocity to be limited to a<br />

specified amount.<br />

VELOCITY ERROR WINDOW – PROFILE POSITION INDEX 0X2104<br />

Type Access Units Range Map PDO Memory<br />

Integer 32 RW 0.1 counts/sec 0 – 500,000,000 YES RF<br />

Description<br />

Also known as the Velocity Tracking Window, this object <strong>de</strong>fines the velocity loop error window. If<br />

the absolute velocity error exceeds this value, then the velocity window bit of the Manufacturer<br />

Status Register object (in<strong>de</strong>x 0x1002, p. 60) is set. The Velocity Window bit will only be cleared<br />

when the velocity error has been within the Velocity Error Window for the timeout period <strong>de</strong>fined in<br />

the Velocity Error Window Time object (in<strong>de</strong>x 0x2120, p. 67).<br />

VELOCITY ERROR WINDOW – PROFILE VELOCITY INDEX 0X606D<br />

Type Access Units Range Map PDO Memory<br />

Unsigned 16 RW 0.1 counts/sec 0 – 65,535 YES RF<br />

Description<br />

Object 606D holds the same value as in<strong>de</strong>x 0x2104. It is inclu<strong>de</strong>d because the <strong>CANopen</strong> Profile<br />

for Drives and Motion Control (DSP 402) mandates it for support of profile velocity mo<strong>de</strong><br />

operation. In the Copley Controls implementation, 0x2104 and 0x606D differ only in the data type.<br />

Object 0x606D is unsigned 16 and 0x2104 is Integer 32. Changes ma<strong>de</strong> to either object affect<br />

both.<br />