<strong>CANopen</strong> Programmer’s <strong>Manual</strong> 3: Device Control, Configuration, and Status<br />

RMS CURRENT CALCULATION PERIOD INDEX 0X2114<br />

Type Access Units Range Map PDO Memory<br />

Integer16 RW milliseconds - YES RF<br />

Description<br />

This sets the period over which the RMS current is calculated. If this value is set to zero, then the<br />

RMS current will be updated each time it is read for the period since the last read. In this case, the<br />

RMS current must be read at least once every 65536 current loop periods (about every 4 seconds)<br />

for the returned RMS values to be accurate.<br />

RMS CURRENT OVER SET PERIOD INDEX 0X2115<br />

Type Access Units Range Map PDO Memory<br />

Integer16 RO 0.01 amps - YES RF<br />

Description<br />

RMS current over the period set in parameter 0x130.<br />

MOTOR PHASE ANGLE INDEX 0X2260<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 R <strong>de</strong>grees 0 - 360 YES R<br />

Description<br />

Motor phase angle, <strong>de</strong>rived from motor commutation.<br />

MOTOR PHASE ANGLE INDEX 0X2262<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RW <strong>de</strong>grees 0 - 360 YES R<br />

Description<br />

Same as 0x2260 but writeable. Writes are only useful when running in diagnostic micro-stepping<br />

mo<strong>de</strong>.<br />

ENCODER PHASE ANGLE INDEX 0X2263<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RO <strong>de</strong>grees 0 - 360 YES R<br />

Description<br />

For feedback types, such as resolver, that can also calculate phase angle information. This<br />

parameter allows the phase information to be read directly.<br />

HALL STATE INDEX 0X2261<br />

Type Access Units Range Map PDO Memory<br />

Integer 16 RO - 0 - 7 YES -<br />

Description<br />

The lower three bits of the returned value give the present state of the Hall input pins.<br />

The Hall state is the value of the Hall lines AFTER the or<strong>de</strong>ring and inversions specified in the Hall<br />

wiring configuration have been applied.<br />