<strong>Copley</strong> Amplifier Parameter Dictionary Amplifier Variables<br />

ASCII DvcNet Macro CAN ID:sub Bank Type Description<br />

0x113 0x114 0x513 0x1015 RF U16 CANopen emergency inhibit time. Units: milliseconds<br />

0x114 0x115 0x514 0x60F9:5<br />

or<br />

0x2381:5<br />

0x115 0x116 0x515 0x2010 R 8 Byte<br />

array<br />

RF U16 Velocity loop Drain (integral bleed). Modifies the effect of velocity loop integral gain.<br />

The higher the Vi Drain value, the faster the integral sum is lowered. Range: 0 to<br />

32,000. Default: 0.<br />

CAN ID 0x60F9 is no longer recommen<strong>de</strong>d. Please use 0x2381.<br />

0x116 0x117 0x516 0x605A RF INT 16 CANopen quick stop option co<strong>de</strong>.<br />

0x117 0x118 0x517 0x605B RF INT 16 CANopen shutdown option co<strong>de</strong>.<br />

0x118 0x119 0x518 0x605C RF INT 16 CANopen disable option co<strong>de</strong>.<br />

0x119 0x11A 0x519 0x605D RF INT 16 CANopen halt option co<strong>de</strong>.<br />

Trajectory buffer access. Used to write formatted data to the <strong>amplifier</strong>’s trajectory<br />

buffer. Used to send PVT segments over the serial port.<br />

0x11A 0x11B 0X51A 0x2080 F* INT 32 Amplifier scaling configuration. This read-only <strong>parameter</strong> <strong>de</strong>fines the units used for<br />

current and voltage readings from the <strong>amplifier</strong>:<br />

0x120 0x121 0x520 0x6510:25<br />

or<br />

0x2384:25<br />

Bits Description<br />

0-1 I<strong>de</strong>ntify units for current readings:<br />

0 0.01 A<br />

1 0.001 A<br />

2 0.0001 A<br />

3 0.00001 A<br />

2-7 Reserved<br />

8-9 I<strong>de</strong>ntify units for voltage readings:<br />

0 0.1 V<br />

1 0.01 V<br />

2 0.001 V<br />

3 0.0001 V<br />

10-31 Reserved<br />

R* U16 Returns the number of axis implemented by this <strong>amplifier</strong>.<br />

CAN ID 0x6510 is no longer recommen<strong>de</strong>d. Please use 0x2384.<br />

0x121 0x122 0x521 0x21B3 RF U16 Network options. Configures the <strong>amplifier</strong>’s network support. The <strong>de</strong>tails of its<br />

meaning <strong>de</strong>pend on the type of network implemented in the <strong>amplifier</strong>.<br />

<strong>Copley</strong> Controls Page 54