<strong>Copley</strong> Amplifier Parameter Dictionary Amplifier Variables<br />

ASCII DvcNet Macro CAN ID:sub Bank Type Description<br />

0x10C 0x10D 0x50C 0x1017 R U16 CANopen Heartbeat Time. The frequency at which the <strong>amplifier</strong> will produce<br />

heartbeat messages. This <strong>parameter</strong> may be set to zero to disable heartbeat<br />

production. Note that only one of the two no<strong>de</strong>-guarding methods may be used at<br />

once. If the Heartbeat Time is non-zero, then the heartbeat protocol is used<br />

regardless of the settings of the CANopen No<strong>de</strong> Guarding Time (p. 53) and<br />

CANopen No<strong>de</strong> Guarding Life Time Factor (p. 53). Units: ms.<br />

0x10D 0x10E 0x50D 0x100C R U16 CANopen No<strong>de</strong> Guarding Time. This <strong>parameter</strong> gives the time between no<strong>de</strong>guarding<br />

requests that are sent from the CANopen master to this <strong>amplifier</strong>. The<br />

<strong>amplifier</strong> will respond to each request with a no<strong>de</strong>-guarding message indicating the<br />

internal state of the <strong>amplifier</strong>.<br />

If the <strong>amplifier</strong> has not received a no<strong>de</strong>-guarding request within the time period<br />

<strong>de</strong>fined by the product of the No<strong>de</strong> Guarding Time and the CANopen No<strong>de</strong> Guarding<br />

Life Time Factor (p. 53), the <strong>amplifier</strong> will treat this lack of requests as a fault<br />

condition. Units: ms.<br />

0x10E 0x10F 0x50E 0x100D R U8 CANopen No<strong>de</strong> Guarding Life Time Factor. This object gives a multiple of the<br />

CANopen No<strong>de</strong> Guarding Time (p. 53). The <strong>amplifier</strong> expects to receive a no<strong>de</strong>guarding<br />

request within the time period <strong>de</strong>fined by the product of the Guarding Time<br />

and the Lifetime Factor. If the <strong>amplifier</strong> has not received a no<strong>de</strong>-guarding request<br />

within this time period, it treats the lack of requests as a fault.<br />

0x10F 0x110 0x50F 0x2325 R INT 32 Registration Offset For Pulse & Direction Mo<strong>de</strong>. When running in pulse & direction<br />

mo<strong>de</strong> (Desired Amplifier State = 23), this <strong>parameter</strong> may be used to inject an offset<br />

into the master position. The offset will immediately be cleared once it has been<br />

applied to the master position, so this <strong>parameter</strong> will normally be read back as zero<br />

when running in pulse and direction mo<strong>de</strong> 23.<br />

0x110 0x111 0x510 0x2404 R INT 32 Time Stamp of Last High Speed Position Capture.<br />

If high speed position capture is enabled, this <strong>parameter</strong> gives the time of the last<br />

capture.<br />

Setting this <strong>parameter</strong> causes the <strong>amplifier</strong> to calculate its position at the set time if<br />

position capture is enabled and the time is recent enough for the data to be<br />

available. The calculated position may be read from Captured Position for High<br />

Speed Position Capture. Units: microseconds.<br />

0x111 0x112 0x511 0x2405 R* INT 32 Captured Position for High Speed Position Capture. Units: counts.<br />

0x112 0x113 0x512 0x2242 R INT 32 Position Enco<strong>de</strong>r Position.Units: counts.<br />