<strong>Copley</strong> Amplifier Parameter Dictionary Amplifier Variables<br />

ASCII DvcNet Macro CAN ID:sub Bank Type Description<br />

5 Enco<strong>de</strong>r feedback error.<br />

6 Motor phasing error.<br />

7 Current output limited.<br />

8 Voltage output limited.<br />

9 Positive limit switch active.<br />

10 Negative limit switch active.<br />

11 Enable input not active.<br />

12 Amplifier is disabled by software.<br />

13 Trying to stop motor.<br />

14 Motor brake activated.<br />

15 PWM outputs disabled.<br />

16 Positive software limit condition.<br />

17 Negative software limit condition.<br />

18 Tracking error.<br />

19 Tracking warning.<br />

20 Amplifier is currently in a reset condition.<br />

21 Position has wrapped. The Position variable cannot increase in<strong>de</strong>finitely. After reaching a<br />

certain value the variable rolls back. This type of counting is called position wrapping or<br />

modulo count.<br />

22 Amplifier fault. An <strong>amplifier</strong> fault that was configured as latching has occurred. For<br />

information on latching faults, see the CME 2 User Gui<strong>de</strong>.<br />

23 Velocity limit has been reached.<br />

24 Acceleration limit has been reached.<br />

25 Tracking Window. Following Error (p. 15) is outsi<strong>de</strong> of Position Tracking Error Limit.<br />

26 Home switch is active.<br />

27 Set if trajectory is running or motor has not yet settled into position (within Position Tracking<br />

Error Limit) at the end of the move. Once the position has settled, the in motion bit won't be<br />

set until the next move starts.<br />

28 Velocity window. Set if the absolute velocity error exceeds the velocity window value.<br />

29 Phase not yet initialized. If the <strong>amplifier</strong> is phasing with no Halls, this bit is set until the<br />

<strong>amplifier</strong> has initialized its phase.<br />

30 Command fault. PWM or other command signal not present. If Allow 100% Output option is<br />

enabled, by a setting Bit 3 of Digital Input Command Configuration (p. 36), this fault will not<br />

<strong>de</strong>tect a missing PWM command.<br />

<strong>Copley</strong> Controls Page 32