<strong>Copley</strong> Amplifier Parameter Dictionary Amplifier Variables<br />
ASCII DvcNet Macro CAN ID:sub Bank Type Description<br />
0x96 0x97 0x496 0x2312 RF U16 Calibration Offset For Analog Reference. This voltage is ad<strong>de</strong>d to the analog<br />
0x97 0x98 0x497 0x6510:10<br />
or<br />
0x2384:10<br />
F* INT16<br />
command input. It is factory-calibrated to give a zero reading for zero input voltage.<br />
Hysteresis Value For Amplifier Over Temperature Cut-Out. Units: <strong>de</strong>grees C.<br />
CAN ID 0x6510 is no longer recommen<strong>de</strong>d. Please use 0x2384.<br />
0x98 0x99 0x498 0x2330 RF U16 Function Generator Configuration. Configures the <strong>amplifier</strong>’s internal function<br />
generator, which can drive the current, velocity, or position loop. Bit-mapped:<br />
Bits Description<br />
0-1 Function co<strong>de</strong> (type of waveform to generate):<br />
Value Description<br />
0 None (disabled).<br />
1 Square wave.<br />
2 Sine wave.<br />
2-11 Reserved for future use.<br />
12 One-shot mo<strong>de</strong>. If bit 12 is set and bit 13 is clear, the function co<strong>de</strong> is reset to zero (disabled)<br />
after one complete waveform. If bits 12 and 13 are both set, the function co<strong>de</strong> is reset to zero<br />
after two waveforms.<br />
13 Invert every other waveform if set.<br />
14-15 Reserved for future use.<br />
The function co<strong>de</strong> programmed into bits 0-1 <strong>de</strong>fines the type of waveform to be generated:<br />
Co<strong>de</strong> Describe<br />
0 None (disabled).<br />
1 Square wave.<br />
2 Sine wave.<br />
Note that the <strong>amplifier</strong> is placed un<strong>de</strong>r control of the function generator by setting<br />
Desired Amplifier State (p. 13) to one of the following values:<br />
4 (function generator drives current loop);<br />
14 (function generator drives velocity loop);<br />
24 (function generator drives position loop in servo mo<strong>de</strong>);<br />
34 (function generator drives position loop in stepper mo<strong>de</strong>).<br />
0x99 0x9A 0x499 0x2331 RF INT16 Function Generator Frequency. Units: Hz.<br />