<strong>Copley</strong> Amplifier Parameter Dictionary Amplifier Variables<br />

ASCII DvcNet Macro CAN ID:sub Bank Type Description<br />

0x96 0x97 0x496 0x2312 RF U16 Calibration Offset For Analog Reference. This voltage is ad<strong>de</strong>d to the analog<br />

0x97 0x98 0x497 0x6510:10<br />

or<br />

0x2384:10<br />

F* INT16<br />

command input. It is factory-calibrated to give a zero reading for zero input voltage.<br />

Hysteresis Value For Amplifier Over Temperature Cut-Out. Units: <strong>de</strong>grees C.<br />

CAN ID 0x6510 is no longer recommen<strong>de</strong>d. Please use 0x2384.<br />

0x98 0x99 0x498 0x2330 RF U16 Function Generator Configuration. Configures the <strong>amplifier</strong>’s internal function<br />

generator, which can drive the current, velocity, or position loop. Bit-mapped:<br />

Bits Description<br />

0-1 Function co<strong>de</strong> (type of waveform to generate):<br />

Value Description<br />

0 None (disabled).<br />

1 Square wave.<br />

2 Sine wave.<br />

2-11 Reserved for future use.<br />

12 One-shot mo<strong>de</strong>. If bit 12 is set and bit 13 is clear, the function co<strong>de</strong> is reset to zero (disabled)<br />

after one complete waveform. If bits 12 and 13 are both set, the function co<strong>de</strong> is reset to zero<br />

after two waveforms.<br />

13 Invert every other waveform if set.<br />

14-15 Reserved for future use.<br />

The function co<strong>de</strong> programmed into bits 0-1 <strong>de</strong>fines the type of waveform to be generated:<br />

Co<strong>de</strong> Describe<br />

0 None (disabled).<br />

1 Square wave.<br />

2 Sine wave.<br />

Note that the <strong>amplifier</strong> is placed un<strong>de</strong>r control of the function generator by setting<br />

Desired Amplifier State (p. 13) to one of the following values:<br />

4 (function generator drives current loop);<br />

14 (function generator drives velocity loop);<br />

24 (function generator drives position loop in servo mo<strong>de</strong>);<br />

34 (function generator drives position loop in stepper mo<strong>de</strong>).<br />

0x99 0x9A 0x499 0x2331 RF INT16 Function Generator Frequency. Units: Hz.<br />

<strong>Copley</strong> Controls Page 30