National Rejectors, Inc. GmbH, Buxtehude ERROR MESSAGES<br />

4 Error messages<br />

Error Remedy<br />

Validator not found –<br />

please check connections<br />

(Program start)<br />

Checksum: defective<br />

(Diagnostics screen)<br />

LED of coin signal line on tester is<br />

not illuminated<br />

(Menu item Tests → Line test)<br />

Solenoid cannot be heard attracting<br />

and releasing acceptance or sorting<br />

gate<br />

(Menu item gate test)<br />

Device cannot be<br />

programmed to Euro<br />

(Menu item WinEuro → Data block<br />

update)<br />

Please return to<br />

diagnostics!<br />

(Exit via X)<br />

Wrong validator (Serial No.)<br />

(Menu item WinEuro → Calibration<br />

coins → Measure)s<br />

- Connect device environment<br />

(see chapter 2 ”Starting up”)<br />

- Check connections/cables of the<br />

device environment<br />

Request coin validator (RAM/<br />

EEPROM) to be repaired by service<br />

technician<br />

- Check cables/plug-in connections<br />

between tester and coin validator<br />

- Ask service technician to check<br />

output level of coin validator<br />

Check entire solenoid module<br />

- Connected coin validator has<br />

already been converted to Euro<br />

- incorrect measuring mode set in<br />

coin validator (see instructions for<br />

coin validator)<br />

Use menu item ”Back” to return to<br />

the diagnostics screen, then exit<br />

program<br />

(see chapter 3 ”Operation”)<br />

Reference validator has not been<br />

programmed for Euro, measure<br />

calibration set with suitable device<br />