National Rejectors, Inc. GmbH, Buxtehude OPERATION<br />
To reset the coin validator data to a specific stand of settings<br />
• highlight the appropriate file using the mouse.<br />
• Confirm this selection by clicking on OK.<br />
Whilst the data is being reset the message Please wait is displayed<br />
and then the diagnostics screen is displayed again. The data has now<br />
been reset to the required previous status.<br />
As the backup files which have been saved at a later date are not<br />
deleted if the coin validator data is reset, this information is also still<br />
available.<br />
Convert coin validator to Euro<br />
With the help of <strong>WinEMP</strong> the connected coin validator can easily and<br />
quickly be converted to accept Euro coins.<br />
Depending on the device type, the conversion to Euro coins can be<br />
undertaken in two different ways. The reference data required to generate<br />
the acceptance bands for Euro coins are included in the device memory of<br />
the new coin validator G-18.mft. All other older coin validators do not<br />
contain this reference data in their memory. For these devices, the<br />
reference data must be generated by inserting so-called calibration discs<br />
in the coin validator before the Euro conversion can take place.<br />
Calibration discs are specific, measured discs, the insertion of which into<br />
the coin validator generates reference values which are used to calculate<br />
acceptance bands for the Euro coins. They have been put together into a<br />
set of four different discs. After using a calibration set 300 times, the discs<br />
would generate false reference data due to the wear on the calibration<br />
discs. For this reason <strong>WinEMP</strong> registers every time the discs are used<br />
and requests the user to measure the calibration set again in order to be<br />
able to compensate for wear as and when required.<br />
A calibration set with a specific number must be allocated to a<br />
specific PC workplace due to the calibration set registration and<br />
may not be used on any other PC.<br />
To measure the calibration discs, a reference device<br />
programmed for Euro must only be used for the measurement of<br />
the calibration set for each coin validator series and also be<br />
assigned to a specific PC workplace. It may not be used with<br />
any other PC. If this is not complied with, the quality of the<br />
programming will suffer.<br />