National Rejectors, Inc. GmbH, Buxtehude OPERATION<br />

To reset the coin validator data to a specific stand of settings<br />

• highlight the appropriate file using the mouse.<br />

• Confirm this selection by clicking on OK.<br />

Whilst the data is being reset the message Please wait is displayed<br />

and then the diagnostics screen is displayed again. The data has now<br />

been reset to the required previous status.<br />

As the backup files which have been saved at a later date are not<br />

deleted if the coin validator data is reset, this information is also still<br />

available.<br />

Convert coin validator to Euro<br />

With the help of <strong>WinEMP</strong> the connected coin validator can easily and<br />

quickly be converted to accept Euro coins.<br />

Depending on the device type, the conversion to Euro coins can be<br />

undertaken in two different ways. The reference data required to generate<br />

the acceptance bands for Euro coins are included in the device memory of<br />

the new coin validator G-18.mft. All other older coin validators do not<br />

contain this reference data in their memory. For these devices, the<br />

reference data must be generated by inserting so-called calibration discs<br />

in the coin validator before the Euro conversion can take place.<br />

Calibration discs are specific, measured discs, the insertion of which into<br />

the coin validator generates reference values which are used to calculate<br />

acceptance bands for the Euro coins. They have been put together into a<br />

set of four different discs. After using a calibration set 300 times, the discs<br />

would generate false reference data due to the wear on the calibration<br />

discs. For this reason <strong>WinEMP</strong> registers every time the discs are used<br />

and requests the user to measure the calibration set again in order to be<br />

able to compensate for wear as and when required.<br />

A calibration set with a specific number must be allocated to a<br />

specific PC workplace due to the calibration set registration and<br />

may not be used on any other PC.<br />

To measure the calibration discs, a reference device<br />

programmed for Euro must only be used for the measurement of<br />

the calibration set for each coin validator series and also be<br />

assigned to a specific PC workplace. It may not be used with<br />

any other PC. If this is not complied with, the quality of the<br />

programming will suffer.<br />