National Rejectors, Inc. GmbH, Buxtehude OPERATION Teach coin channels If you wish to allocate a new coin type or token to a coin channel, you do this using the real coin or false coin adjustment screen: • On the diagnostics screen in the sub-menu SETTINGS select the menu item ADJUSTMENT. The screen message Please insert 20 genuine coins (1 denomination) is displayed. • Insert 20 coins of the new coin type into the coin validator. For validation purposes, the screen display indicates the coins inserted and counts down from 20 to 0. After the 20th coin has been inserted, the real coin adjustment screen is displayed (see page 22). If at least one coin channel is found to which the coin type inserted has been allocated (percentage under Rate %), no additional coin channel can be taught. The channel assigned to that coin type must be adjusted (see section ”Adjust coin acceptance band” in this chapter). The coin validator has saved the values of the inserted coins. • Click on the sliding bar of the coin channel to which the coin type is to be assigned. The saved values are assigned to the appropriate coin channel with 100%. If the acceptance band of the coin channel is to be adjusted and the relationship between a high real coin acceptance and rejection of false coins is to be optimized, please follow the procedure from step 3 onwards in the section ”Adjust coin acceptance band” in this chapter. 24
National Rejectors, Inc. GmbH, Buxtehude OPERATION Undo entry Using the menu item RESTORE the WinEMP software enables program changes made to the coin validator to be reversed i.e. the coin validation data can be reset to any setting. To do this, the settings of the coin validator must always be made using the same PC as the back-up files have been saved on the computer’s hard disc and are also retrieved from the hard disc. When the software WinEMP recognizes the coin validator and when the data is saved in the coin validator after a security query has been made, it creates a backup file in the archive folder. If you wish to reverse the settings you have made, please proceed as follows: • On the diagnostics screen (see page 10) select the menu item RESTORE. The dialog window Loading backup data is displayed. This dialog window lists all backup files with settings for the connected coin validator saved on the hard disc of your PC and they can be identified above all by the first and last column: • Date and time of adjustment • Device type • Device number • Serial number • File name 25
- Page 1 and 2: Technical documentation WinEMP The
- Page 3 and 4: National Rejectors, Inc. GmbH, Buxt
- Page 5 and 6: National Rejectors, Inc. GmbH, Buxt
- Page 7 and 8: National Rejectors, Inc. GmbH, Buxt
- Page 9 and 10: National Rejectors, Inc. GmbH, Buxt
- Page 11 and 12: National Rejectors, Inc. GmbH, Buxt
- Page 13 and 14: National Rejectors, Inc. GmbH, Buxt
- Page 15 and 16: National Rejectors, Inc. GmbH, Buxt
- Page 17 and 18: National Rejectors, Inc. GmbH, Buxt
- Page 19 and 20: National Rejectors, Inc. GmbH, Buxt
- Page 21 and 22: National Rejectors, Inc. GmbH, Buxt
- Page 23: National Rejectors, Inc. GmbH, Buxt
- Page 27 and 28: National Rejectors, Inc. GmbH, Buxt
- Page 29 and 30: National Rejectors, Inc. GmbH, Buxt
- Page 31 and 32: National Rejectors, Inc. GmbH, Buxt
- Page 33 and 34: National Rejectors, Inc. GmbH, Buxt
- Page 35 and 36: National Rejectors, Inc. GmbH, Buxt
- Page 37 and 38: National Rejectors, Inc. GmbH, Buxt
- Page 39 and 40: National Rejectors, Inc. GmbH, Buxt
- Page 41 and 42: G-18.2900 Hardware adaptation withi
- Page 43: WinEMP Reference list for data bloc
National Rejectors, Inc. GmbH, Buxtehude OPERATION<br />
Undo entry<br />
Using the menu item RESTORE the <strong>WinEMP</strong> software enables program<br />
changes made to the coin validator to be reversed i.e. the coin validation<br />
data can be reset to any setting.<br />
To do this, the settings of the coin validator must always be made<br />
using the same PC as the back-up files have been saved on the<br />
computer’s hard disc and are also retrieved from the hard disc.<br />
When the software <strong>WinEMP</strong> recognizes the coin validator and when the<br />
data is saved in the coin validator after a security query has been made, it<br />
creates a backup file in the archive folder.<br />
If you wish to reverse the settings you have made, please proceed as<br />
follows:<br />
• On the diagnostics screen (see page 10) select the<br />
menu item RESTORE.<br />
The dialog window<br />
Loading backup<br />
data is displayed.<br />
This dialog window<br />
lists all backup files<br />
with settings for the<br />
connected coin<br />
validator saved on the<br />
hard disc of your PC<br />
and they can be<br />
identified above all by<br />
the first and last<br />
column:<br />
• Date and time of adjustment<br />
• Device type<br />
• Device number<br />
• Serial number<br />
• File name<br />
25